dc.description.abstract | Synchrotron radiation microcomputed tomography (SR-mu CT) can provide non-destructive three-dimensional investigation for soft tissue with high resolution. The aim of this study is to evaluate technical improvements in microcomputed tomographic imaging of human lung tissue using a synchrotron radiation source at the 6C biomedical beamline. SR-mu CT images of excised human lung tissue (6 mm vertically and 10 mm horizontally sized) were explored at the 6C biomedical beamline in the Pohang accelerator laboratory (Pohang, Republic of Korea) using phase retrieval methods with a modified Bronnikov algorithm. Experimental data collection was performed with changes in the following conditions: the presence of a graphite attenuator, sample to detector distance, the presence of different scintillators and increasing pixel sizes. We identified that the resolution of lung tissue images was sufficiently enhanced when the graphite attenuator was not applied, 550 mm of sample to detector distance, with Cadmium tungsten (CdWO4) scintillator and twice binning of the pixel data and could be comparable with images from pathologic examination. Refinement of SR-mu CT techniques for soft tissue originating from the human body would advance the potential clinical application of synchrotron radiation in the near future. | - |
dc.format.extent | 11 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | John Wiley & Sons Inc. | - |
dc.title | Imaging optimisation process of human lung tissue using synchrotron radiation microcomputed tomography in PLS-II | - |
dc.type | Article | - |
dc.publisher.location | 미국 | - |
dc.identifier.doi | 10.1002/xrs.3324 | - |
dc.identifier.scopusid | 2-s2.0-85147155871 | - |
dc.identifier.wosid | 000917760900001 | - |
dc.identifier.bibliographicCitation | X-Ray Spectrometry, v.52, no.3, pp 110 - 120 | - |
dc.citation.title | X-Ray Spectrometry | - |
dc.citation.volume | 52 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 110 | - |
dc.citation.endPage | 120 | - |
dc.type.docType | Article; Early Access | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Spectroscopy | - |
dc.relation.journalWebOfScienceCategory | Spectroscopy | - |
dc.subject.keywordPlus | COMPUTED-TOMOGRAPHY | - |
dc.subject.keywordPlus | ADENOCARCINOMA | - |
dc.subject.keywordPlus | OPTICS | - |
dc.subject.keywordPlus | IMAGES | - |
dc.subject.keywordAuthor | lung | - |
dc.subject.keywordAuthor | microtomography | - |
dc.subject.keywordAuthor | synchrotron radiation | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(31538) 22, Soonchunhyang-ro, Asan-si, Chungcheongnam-do, Republic of Korea+82-41-530-1114
COPYRIGHT 2021 by SOONCHUNHYANG UNIVERSITY ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.