Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Reducing contrast-agent volume and radiation dose in CT with 90-kVp tube voltage, high tube current modulation, and advanced iteration algorithm

Full metadata record
DC Field Value Language
dc.contributor.authorPark, Min Su-
dc.contributor.authorHa, Hong Il-
dc.contributor.authorAhn, Jhii-Hyun-
dc.contributor.authorLee, In Jae-
dc.contributor.authorLim, Hyun Kyung-
dc.date.accessioned2023-12-13T21:31:28Z-
dc.date.available2023-12-13T21:31:28Z-
dc.date.issued2023-06-
dc.identifier.issn1932-6203-
dc.identifier.urihttps://scholarworks.bwise.kr/sch/handle/2021.sw.sch/25118-
dc.description.abstractIncreasing utilization of computed tomography (CT) has raised concerns regarding CT radiation dose and technology has been developed to achieve an appropriate balance between image quality, radiation dose, and the amount of contrast material. This study was planned to evaluate the image quality and radiation dose in pancreatic dynamic computed tomography (PDCT) with 90-kVp tube voltage and reduction of the standard amount of contrast agent, compared with 100-kVp PDCT of the research hospital's convention. Total of 51 patients with both CT protocols were included. The average Hounsfield units (HU) values of the abdominal organs and image noise were measured for objective image quality analysis. Two radiologists evaluated five categories of image qualities such as subjective image noise, visibility of small structure, beam hardening or streak artifact, lesion conspicuity and overall diagnostic performance for subjective image quality analysis. The total amount of contrast agent, radiation dose, and image noise decreased in the low-kVp group, by 24.4%, 31.7%, and 20.6%, respectively (p < 0.001). The intraobserver and interobserver agreements were moderate to substantial (k = 0.4-0.8). The contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), and figure of merit of the almost organs except psoas muscle in the low-kVp group were significantly higher (p < 0.001). Except for lesion conspicuity, both reviewers judged that subjective image quality of the 90-kVp group was better (p < 0.001). With 90-kVp tube voltage, 25% reduced contrast agent volume with advanced iteration algorithm and high tube current modulation achieved radiation dose reduction of 31.7%, as well as better image quality and diagnostic confidence.-
dc.language영어-
dc.language.isoENG-
dc.publisherPublic Library of Science-
dc.titleReducing contrast-agent volume and radiation dose in CT with 90-kVp tube voltage, high tube current modulation, and advanced iteration algorithm-
dc.typeArticle-
dc.publisher.location미국-
dc.identifier.doi10.1371/journal.pone.0287214-
dc.identifier.scopusid2-s2.0-85163404716-
dc.identifier.wosid001017691200024-
dc.identifier.bibliographicCitationPLoS ONE, v.18, no.6-
dc.citation.titlePLoS ONE-
dc.citation.volume18-
dc.citation.number6-
dc.type.docTypeArticle-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaScience & Technology - Other Topics-
dc.relation.journalWebOfScienceCategoryMultidisciplinary Sciences-
dc.subject.keywordPlusIMAGE QUALITY-
dc.subject.keywordPlusABDOMINAL CT-
dc.subject.keywordPlusRECONSTRUCTION ALGORITHM-
dc.subject.keywordPlusOPTIMIZATION-
dc.subject.keywordPlusREDUCTION-
dc.subject.keywordPlusPHANTOM-
dc.subject.keywordPlusKILOVOLTAGE-
dc.subject.keywordPlusEXPOSURE-
dc.subject.keywordPlusSIZE-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Radiology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lim, Hyun Kyung photo

Lim, Hyun Kyung
College of Medicine (Department of Radiology)
Read more

Altmetrics

Total Views & Downloads

BROWSE