Development of a Diagnosis and Evaluation System for Hemiplegic Patients Post-Stroke Based on Motion Recognition Tracking and Analysis of Wrist Joint Kinematics
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Subok | - |
dc.contributor.author | Park, Seoho | - |
dc.contributor.author | Lee, Onseok | - |
dc.date.accessioned | 2021-08-11T08:34:04Z | - |
dc.date.available | 2021-08-11T08:34:04Z | - |
dc.date.issued | 2020-08 | - |
dc.identifier.issn | 1424-8220 | - |
dc.identifier.issn | 1424-3210 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/2601 | - |
dc.description.abstract | An inexperienced therapist lacks the analysis of a patient's movement. In addition, the patient does not receive objective feedback from the therapist due to the visual subjective judgment. The aim is to provide a guide for in-depth rehabilitation therapy in virtual space by continuously tracking the user's wrist joint during Leap Motion Controller (LMC) activities and present the basic data to confirm steady therapy results in real-time. The conventional Box and Block Test (BBT) is commonly used in upper extremity rehabilitation therapy. It was modeled in proportion to the actual size and Auto Desk Inventor was used to perform the 3D modeling work. The created 3D object was then implemented in C # through Unity5.6.2p4 based on LMC. After obtaining a wrist joint motion value, the motion was analyzed by 3D graph. Healthy subjects (23 males and 25 females, n = 48) were enrolled in this study. There was no statistically significant counting difference between conventional BBT and system BBT. This indicates the possibility of effective diagnosis and evaluation of hemiplegic patients post-stroke. We can keep track of wrist joints, check real-time continuous feedback in the implemented virtual space, and provide the basic data for an LMC-based quantitative rehabilitation therapy guide. | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | Multidisciplinary Digital Publishing Institute (MDPI) | - |
dc.title | Development of a Diagnosis and Evaluation System for Hemiplegic Patients Post-Stroke Based on Motion Recognition Tracking and Analysis of Wrist Joint Kinematics | - |
dc.type | Article | - |
dc.publisher.location | 스위스 | - |
dc.identifier.doi | 10.3390/s20164548 | - |
dc.identifier.scopusid | 2-s2.0-85089413255 | - |
dc.identifier.wosid | 000565569800001 | - |
dc.identifier.bibliographicCitation | Sensors, v.20, no.16 | - |
dc.citation.title | Sensors | - |
dc.citation.volume | 20 | - |
dc.citation.number | 16 | - |
dc.type.docType | Article | - |
dc.description.isOpenAccess | Y | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Chemistry | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Instruments & Instrumentation | - |
dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
dc.subject.keywordPlus | INDUCED MOVEMENT THERAPY | - |
dc.subject.keywordPlus | UPPER EXTREMITY FUNCTION | - |
dc.subject.keywordPlus | VIRTUAL-REALITY | - |
dc.subject.keywordPlus | STROKE REHABILITATION | - |
dc.subject.keywordPlus | SUBACUTE STROKE | - |
dc.subject.keywordPlus | MOTOR RECOVERY | - |
dc.subject.keywordPlus | ADULT NORMS | - |
dc.subject.keywordPlus | HAND | - |
dc.subject.keywordPlus | REORGANIZATION | - |
dc.subject.keywordPlus | CONTROLLER | - |
dc.subject.keywordAuthor | leap motion controller | - |
dc.subject.keywordAuthor | box and block test | - |
dc.subject.keywordAuthor | hand tracking | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(31538) 22, Soonchunhyang-ro, Asan-si, Chungcheongnam-do, Republic of Korea+82-41-530-1114
COPYRIGHT 2021 by SOONCHUNHYANG UNIVERSITY ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.