Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Validity of Modified STOP-Bang Questionnaire as a Screening Tool for Obstructive Sleep Apnea

Full metadata record
DC Field Value Language
dc.contributor.authorLee, Min-Ki-
dc.contributor.authorChoi, Ji Ho-
dc.contributor.authorLee, Jae Yong-
dc.date.accessioned2024-06-11T08:00:59Z-
dc.date.available2024-06-11T08:00:59Z-
dc.date.issued2024-02-
dc.identifier.issn0003-4894-
dc.identifier.issn1943-572X-
dc.identifier.urihttps://scholarworks.bwise.kr/sch/handle/2021.sw.sch/26166-
dc.description.abstractObjectives: The aim of this study was to evaluate the validity of a modified STOP-Bang questionnaire with different body mass index reference as a screening tool for obstructive sleep apnea in Korean population.Methods: The medical records of 1417 participants who underwent overnight Level I polysomnography were retrospectively analyzed. Predictive parameters were calculated for each of the 3 groups classified by obstructive sleep apnea severity with a cut-off value of 3 or 4. Responses to modified and traditional questionnaires were comparatively analyzed by receiver-operator characteristic curves and area under the receiver-operator characteristic curves.Results: The optimal cut-off values of the modified and traditional questionnaires were both 3.5. The area under the receiver-operator characteristic curve of modified STOP-Bang questionnaire for any obstructive sleep apnea group was 0.786 +/- 0.018, which was significantly higher than that of the traditional questionnaire. The modified STOP-Bang questionnaire with a cut-off value >= 4 showed significantly higher sensitivity than the traditional one for any obstructive sleep apnea group. The diagnostic accuracy of the modified questionnaire was also significantly higher for the any obstructive sleep apnea group when the cut-off value was 4.Conclusion: The modified STOP-Bang questionnaire, with a cut-off value of 4, can be used as an alternative to the traditional screening tool for the Korean population.-
dc.format.extent6-
dc.language영어-
dc.language.isoENG-
dc.publisherSAGE PUBLICATIONS INC-
dc.titleValidity of Modified STOP-Bang Questionnaire as a Screening Tool for Obstructive Sleep Apnea-
dc.typeArticle-
dc.publisher.location미국-
dc.identifier.doi10.1177/00034894241234156-
dc.identifier.scopusid2-s2.0-85186449604-
dc.identifier.wosid001169568500001-
dc.identifier.bibliographicCitationANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, v.133, no.6, pp 554 - 559-
dc.citation.titleANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY-
dc.citation.volume133-
dc.citation.number6-
dc.citation.startPage554-
dc.citation.endPage559-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaOtorhinolaryngology-
dc.relation.journalWebOfScienceCategoryOtorhinolaryngology-
dc.subject.keywordAuthorobstructive sleep apnea-
dc.subject.keywordAuthorscreening test-
dc.subject.keywordAuthorquestionnaire-
dc.subject.keywordAuthorbody mass index-
dc.subject.keywordAuthorsensitivity-
dc.subject.keywordAuthordiagnostic accuracy-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Otorhinolaryngology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Jae Yong photo

Lee, Jae Yong
College of Medicine (Department of Otorhinolaryngology)
Read more

Altmetrics

Total Views & Downloads

BROWSE