Effective and Practical Complete Blood Count Delta Check Method and Criteria for the Quality Control of Automated Hematology Analyzers

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Min-Sun-
dc.contributor.authorPark, Chan-Jeoung-
dc.contributor.authorNamgoong, Seung-
dc.contributor.authorKim, Seung-Il-
dc.contributor.authorCho, Young-Uk-
dc.contributor.authorJang, Seongsoo-
dc.date.accessioned2024-08-13T09:36:42Z-
dc.date.available2024-08-13T09:36:42Z-
dc.date.issued2023-09-
dc.identifier.issn2234-3806-
dc.identifier.issn2234-3814-
dc.identifier.urihttps://scholarworks.bwise.kr/sch/handle/2021.sw.sch/26480-
dc.description.abstractBackground: Delta checks increase patient safety by identifying automated hematology analyzer errors. International standards and guidelines for the complete blood count (CBC) delta check method have not been established. We established an effective, practical CBC delta check method and criteria.Methods: We assessed five delta check methods for nine CBC items (Hb, mean corpus-cular volume, platelet count, white blood cell [WBC] count, and five-part WBC differential counts) using 219,804 blood samples from outpatients and inpatients collected over nine months. We adopted the best method and criteria and evaluated them using 42,652 CBC samples collected over two weeks with a new workflow algorithm for identifying test errors and corrections for Hb and platelet count.Results: The median delta check time interval was 1 and 21 days for inpatients and out-patients (range, 1-20 and 1-222 days), respectively. We used delta values at 99.5% as delta check criteria; the criteria varied among the five methods and between outpatients and inpatients. The delta percent change (DPC)/reference range (RR) rate performed best as the delta check for CBC items. Using the new DPC/RR rate method, 1.7% of total test results exceeded the delta check criteria; the retesting and resampling rates were 0.5% and 0.001%, respectively.Conclusions: We developed an effective, practical delta check method, including RRs and delta check time intervals, and delta check criteria for nine CBC items. The criteria differ between outpatients and inpatients. Using the new workflow algorithm, we can identify the causes of criterion exceedance and report correct test results.-
dc.format.extent7-
dc.language영어-
dc.language.isoENG-
dc.publisherKOREAN SOC LABORATORY MEDICINE-
dc.titleEffective and Practical Complete Blood Count Delta Check Method and Criteria for the Quality Control of Automated Hematology Analyzers-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.doi10.3343/alm.2023.43.5.418-
dc.identifier.scopusid2-s2.0-85153432627-
dc.identifier.wosid000989061000004-
dc.identifier.bibliographicCitationANNALS OF LABORATORY MEDICINE, v.43, no.5, pp 418 - 424-
dc.citation.titleANNALS OF LABORATORY MEDICINE-
dc.citation.volume43-
dc.citation.number5-
dc.citation.startPage418-
dc.citation.endPage424-
dc.type.docTypeArticle-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaMedical Laboratory Technology-
dc.relation.journalWebOfScienceCategoryMedical Laboratory Technology-
dc.subject.keywordPlusBIOLOGICAL VARIATION-
dc.subject.keywordAuthorBlood cell counts-
dc.subject.keywordAuthorDelta check method-
dc.subject.keywordAuthorDelta check criteria-
dc.subject.keywordAuthorQuality control-
dc.subject.keywordAuthorAutomated hematology analyzer-
dc.subject.keywordAuthorAutomation-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Clinical Pathology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE