Detailed Information

Cited 1 time in webofscience Cited 1 time in scopus
Metadata Downloads

Use of the Subcutaneous Triptorelin Stimulation Test for Diagnosis of Central Precocious Pubertyopen access

Authors
Ahn, JungminLee, YounginGim, SeongminJeong, Hwalrim
Issue Date
Nov-2023
Publisher
MDPI AG
Keywords
precocious puberty; gonadorelin; triptorelin; GnRH stimulation test
Citation
Children (Basel) , v.10, no.11
Journal Title
Children (Basel)
Volume
10
Number
11
URI
https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/26624
DOI
10.3390/children10111830
ISSN
2227-9067
2227-9067
Abstract
Background: The gold standard gonadotropin-releasing hormone (GnRH) stimulation test uses the response to intravenously injected gonadorelin to diagnose central precocious puberty (CPP). However, gonadorelin is not always readily available. Objective: This study investigated the diagnostic efficacy of the subcutaneous triptorelin test and the optimal blood sampling time for diagnosis of CPP. Methods: This study retrospectively examined the medical records of 220 girls who had undergone either the triptorelin or gonadorelin test and compared their clinical characteristics. We retrospectively compared clinical parameters between girls diagnosed with CPP (n = 111) and idiopathic premature thelarche (IPT) (n = 109) using three different diagnostic methods: the gonadorelin, triptorelin 120 min, and triptorelin 180 min tests. The diagnostic ability of the stimulated luteinizing hormone (LH) concentration in the triptorelin test for CPP was evaluated using receiver operating characteristic (ROC) analysis. Results: The CPP group exhibited higher basal and peak gonadotropin levels, more advanced bone age, and a lower body mass index standard deviation score than the IPT group. In the gonadorelin test group, all girls with CPP exhibited a peak LH response 30-60 min after intravenous gonadorelin injection. In the triptorelin test group, most girls with CPP exhibited a peak LH response 60-180 min after subcutaneous triptorelin injection (n = 68). On the ROC curve, a peak LH concentration of >= 4.52 IU/L at 120 min had the highest CPP diagnostic accuracy, with sensitivity and specificity of 100% and 95.83%, respectively.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Pediatrics > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jeong, Hwal Rim photo

Jeong, Hwal Rim
College of Medicine (Department of Pediatrics)
Read more

Altmetrics

Total Views & Downloads

BROWSE