Efficacy of a modified double-guidewire technique using an uneven double lumen cannula (uneven method) in patients with surgically altered gastrointestinal anatomy (with video)
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Takenaka, Mamoru | - |
dc.contributor.author | Minaga, Kosuke | - |
dc.contributor.author | Kamata, Ken | - |
dc.contributor.author | Yamao, Kentaro | - |
dc.contributor.author | Yoshikawa, Tomoe | - |
dc.contributor.author | Ishikawa, Rei | - |
dc.contributor.author | Okamoto, Ayana | - |
dc.contributor.author | Yamazaki, Tomohiro | - |
dc.contributor.author | Nakai, Atsushi | - |
dc.contributor.author | Omoto, Shunsuke | - |
dc.contributor.author | Komeda, Yoriaki | - |
dc.contributor.author | Sakurai, Toshiharu | - |
dc.contributor.author | Watanabe, Tomohiro | - |
dc.contributor.author | Nishida, Naoshi | - |
dc.contributor.author | Chiba, Yasutaka | - |
dc.contributor.author | Kwon, Chang-Il | - |
dc.contributor.author | Jeong, Seok | - |
dc.contributor.author | Lee, Tae Hoon | - |
dc.contributor.author | Kudo, Masatoshi | - |
dc.date.accessioned | 2021-08-11T08:37:30Z | - |
dc.date.available | 2021-08-11T08:37:30Z | - |
dc.date.issued | 2020-03 | - |
dc.identifier.issn | 0930-2794 | - |
dc.identifier.issn | 1432-2218 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/3073 | - |
dc.description.abstract | Background Balloon enteroscopy-assisted endoscopic retrograde cholangiopancreatography (BE-ERCP) has been reported to be effective for patients with surgically altered gastrointestinal anatomy. However, selective biliary cannulation remains difficult in BE-ERCP. We examined the usefulness of a modified double-guidewire technique using an uneven double lumen cannula (the uneven method) for BE-ERCP in patients with surgically altered gastrointestinal anatomy. Methods To clarify the usefulness of the uneven method for selective biliary cannulation in BE-ERCP in comparison to the pancreatic guidewire (PGW) method, 40 patients with surgically altered gastrointestinal anatomy who underwent BE-ERCP with successful placement of a guidewire in the pancreatic duct were evaluated. The uneven method was used in 18 cases (uneven group) and the PGW method was used in the remaining 22 cases (PGW group). Results The technical success rate of biliary cannulation was higher in the uneven group than in the PGW group (83.3 vs. 59.0%; P = 0.165). In addition, the time to biliary cannulation were significantly shorter in the uneven group than in the PGW group (6 vs. 18 min; P = 0.004; respectively). In the PGW group, post-ERCP pancreatitis (PEP) occurred in 3 of 22 cases (13.6%). No adverse events, including PEP, occurred in the uneven group. Conclusions The uneven method may be a useful option of selective biliary cannulation in BE-ERCP for the patients with surgically altered gastrointestinal anatomy. | - |
dc.format.extent | 10 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | Springer Verlag | - |
dc.title | Efficacy of a modified double-guidewire technique using an uneven double lumen cannula (uneven method) in patients with surgically altered gastrointestinal anatomy (with video) | - |
dc.type | Article | - |
dc.publisher.location | 미국 | - |
dc.identifier.doi | 10.1007/s00464-019-07228-5 | - |
dc.identifier.scopusid | 2-s2.0-85074720118 | - |
dc.identifier.wosid | 000493363200001 | - |
dc.identifier.bibliographicCitation | Surgical Endoscopy, v.34, no.3, pp 1432 - 1441 | - |
dc.citation.title | Surgical Endoscopy | - |
dc.citation.volume | 34 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 1432 | - |
dc.citation.endPage | 1441 | - |
dc.type.docType | Article | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Surgery | - |
dc.relation.journalWebOfScienceCategory | Surgery | - |
dc.subject.keywordPlus | SELECTIVE BILIARY CANNULATION | - |
dc.subject.keywordPlus | ENTEROSCOPY-ASSISTED ERCP | - |
dc.subject.keywordPlus | BILE-DUCT CANNULATION | - |
dc.subject.keywordPlus | GASTRECTOMY | - |
dc.subject.keywordPlus | PLACEMENT | - |
dc.subject.keywordPlus | STONES | - |
dc.subject.keywordAuthor | ERCP | - |
dc.subject.keywordAuthor | Balloon enteroscopy-assisted ERCP | - |
dc.subject.keywordAuthor | Patients with surgically altered gastrointestinal anatomy | - |
dc.subject.keywordAuthor | The uneven method | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(31538) 22, Soonchunhyang-ro, Asan-si, Chungcheongnam-do, Republic of Korea+82-41-530-1114
COPYRIGHT 2021 by SOONCHUNHYANG UNIVERSITY ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.