Prospective multicenter international study on the outcomes of a newly developed self-approximating lumen-apposing metallic stent for drainage of pancreatic fluid collections and endoscopic necrosectomy
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Teoh, Anthony Yuen Bun | - |
dc.contributor.author | Bapaye, Amol | - |
dc.contributor.author | Lakhtakia, Sundeep | - |
dc.contributor.author | Ratanachu, Thawee | - |
dc.contributor.author | Reknimitr, Rungsun | - |
dc.contributor.author | Chan, Shannon Melissa | - |
dc.contributor.author | Choi, Hyun Jong | - |
dc.contributor.author | Gadhikar, Harshal P. | - |
dc.contributor.author | Kongkam, Pradermchai | - |
dc.contributor.author | Korrapati, Sravan Kumar | - |
dc.contributor.author | Lee, Yun Nah | - |
dc.contributor.author | Medarapalem, Jahangeer | - |
dc.contributor.author | Ridtitid, Wiriyaporn | - |
dc.contributor.author | Moon, Jong Ho | - |
dc.date.accessioned | 2021-08-11T08:37:32Z | - |
dc.date.available | 2021-08-11T08:37:32Z | - |
dc.date.issued | 2020-03 | - |
dc.identifier.issn | 0915-5635 | - |
dc.identifier.issn | 1443-1661 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/3077 | - |
dc.description.abstract | Background A novel self-approximating lumen-apposing metallic stent (LAMS; Niti-S Spaxus, Taewoong Medical, Gyeonggi-do, Korea) has recently become available. The aim of the present study was to evaluate the outcomes for drainage of pancreatic fluid collections (PFC). Methods This was a prospective international multicentered study conducted in six high-volume institutions across Asia. Consecutive patients suffering from pancreatic pseudocyst or walled-off pancreatic necrosis (WOPN) requiring endoscopic ultrasonography-guided drainage were recruited. Outcomes included technical and clinical success, adverse events, procedural events, interventions through the stent and recurrence rates. Results Between August 2016 and November 2017, 59 patients were recruited to this study. Thirty-nine patients (66.1%) had WOPN and mean (SD) size of PFC was 11.5 (5.1) cm. Technical and clinical success rates were 100%. Mean (SD) procedural time was 35.0 (17.2) minutes. Sixteen-millimeter stents were used in 66.1% of the patients. Fifty-four sessions of necrosectomy were carried out with the stent in situ in 17 patients. Stent-related adverse event (AE) rate was 6.8%. Three patients (5.1%) suffered from bleeding after stenting and one required angiographic embolization. Two patients (3.4%) suffered from recurrence during a mean (SD) follow-up time of 325.6 (355.5) days. There were no differences in outcomes between those with pseudocysts or WOPN except for the duration of hospital stay (P = 0.012). Conclusion Use of a self-approximating LAMS for drainage of PFC was safe and effective. Endoscopic necrosectomy could be carried out through the stent with ease. The device was associated with a low rate of stent-related AE. | - |
dc.format.extent | 8 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | Blackwell Publishing Inc. | - |
dc.title | Prospective multicenter international study on the outcomes of a newly developed self-approximating lumen-apposing metallic stent for drainage of pancreatic fluid collections and endoscopic necrosectomy | - |
dc.type | Article | - |
dc.publisher.location | 미국 | - |
dc.identifier.doi | 10.1111/den.13494 | - |
dc.identifier.wosid | 000484301400001 | - |
dc.identifier.bibliographicCitation | Digestive Endoscopy, v.32, no.3, pp 391 - 398 | - |
dc.citation.title | Digestive Endoscopy | - |
dc.citation.volume | 32 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 391 | - |
dc.citation.endPage | 398 | - |
dc.type.docType | Article | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Gastroenterology & Hepatology | - |
dc.relation.journalResearchArea | Surgery | - |
dc.relation.journalWebOfScienceCategory | Gastroenterology & Hepatology | - |
dc.relation.journalWebOfScienceCategory | Surgery | - |
dc.subject.keywordPlus | WALLED-OFF NECROSIS | - |
dc.subject.keywordPlus | GALLBLADDER DRAINAGE | - |
dc.subject.keywordPlus | GUIDED DRAINAGE | - |
dc.subject.keywordPlus | PLASTIC STENTS | - |
dc.subject.keywordPlus | GASTROJEJUNOSTOMY | - |
dc.subject.keywordPlus | MANAGEMENT | - |
dc.subject.keywordPlus | LAMS | - |
dc.subject.keywordAuthor | EUS-guided cystogastrostomy | - |
dc.subject.keywordAuthor | lumen-apposing stent | - |
dc.subject.keywordAuthor | pancreatic fluid collection | - |
dc.subject.keywordAuthor | pseudocyst | - |
dc.subject.keywordAuthor | walled-off pancreatic collection | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(31538) 22, Soonchunhyang-ro, Asan-si, Chungcheongnam-do, Republic of Korea+82-41-530-1114
COPYRIGHT 2021 by SOONCHUNHYANG UNIVERSITY ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.