Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

반응성 형질세포와 악성 형질세포 감별을 위한 형질세포 선별튜브의 유용성 평가Utility of Plasma Cell Screening Tube Kit to Differentiate Neoplastic Plasma Cells from Reactive Plasma Cells

Other Titles
Utility of Plasma Cell Screening Tube Kit to Differentiate Neoplastic Plasma Cells from Reactive Plasma Cells
Authors
방해인최태윤
Issue Date
2020
Publisher
대한진단검사의학회
Keywords
Flow cytometry; Immunophenotyping; Multiple myeloma; Plasma cells; Plasma cell neoplasm; Plasma cell dyscrasias
Citation
Laboratory Medicine Online, v.10, no.4, pp 314 - 320
Pages
7
Journal Title
Laboratory Medicine Online
Volume
10
Number
4
Start Page
314
End Page
320
URI
https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/3385
DOI
10.47429/lmo.2020.10.4.314
ISSN
2093-6338
Abstract
Flow cytometry is a powerful tool for analysis of hematologic malignancies, that provides rapid, quantitative, and multiparametric analysis of heterogeneous cell populations, but requires standardization because of complexities in panel design and interpretation. Here, we compared the Plasma Cell Screening Tube (PCST) kit (Cytognos, Spain) in conjunction with EuroFlow antibody panels for standardization of flow cytometry to a conventional method for diagnosis of plasma cell dyscrasias. Thirty-nine bone marrow samples and one peripheral blood sample from 40 patients were tested. Thirty-three patients were diagnosed with multiple myeloma (MM), and seven were in a reactive state. In PCST implementation, eight antibodies were used for staining, including anti-CD45-Pacific Blue, anti-CD19-PECy7, anti-CD138-OC515, anti-CD38-FITC, anti-CD56-PE, anti-β2-microglobulin-PerCPCy5.5, anti-kappa-APC, and anti-lambda-APC-C750. Plasma cells were initially identified using CD38 and CD138; thereafter, CD38+, CD138+ gated cells were analyzed for CD56, CD19, CD45, cytoplasmic kappa, cytoplasmic lambda, and β2-microglobulin. Conventional flow cytometry was performed with six monoclonal antibodies, including anti-CD56-FITC, anti-kappa-FITC, anti-CD19-PE, anti-lambda-PE, anti-CD138-PECy5, and anti-CD45-PECy7 (Beckman Coulter, USA). Monoclonal plasma cells with cytoplasmic light-chain restriction were detected in 30 of 33 (90.9%) MM cases by conventional methods, and 32 of 33 (97.0%) MM cases with the PCST method. No differences were noted between PCST and the conventional method in immunophenotyping and plasma cell percentages (P=0.323). Among plasma cells, levels (%) were significantly higher by the PCST approach than those in the conventional method (97.6% vs 95.8%, P=0.010). PCST exhibited better performance for plasma cell dyscrasias diagnosis, and could improve laboratory efficiency and quality.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Clinical Pathology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Bang, Hae In photo

Bang, Hae In
College of Medicine (Department of Clinical Pathology)
Read more

Altmetrics

Total Views & Downloads

BROWSE