Dosing study of esmolol for reducing hemodynamic changes during lightwand intubation
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kang Jin Ku | - |
dc.contributor.author | Yoo Sie Hyeon | - |
dc.contributor.author | 정진헌 | - |
dc.contributor.author | Kim Nan Seol | - |
dc.contributor.author | 정호순 | - |
dc.contributor.author | 서용한 | - |
dc.contributor.author | Chun Hea Rim | - |
dc.contributor.author | 공형윤 | - |
dc.contributor.author | Son Hee Dong | - |
dc.contributor.author | Kim A Joo | - |
dc.date.accessioned | 2021-08-11T08:40:33Z | - |
dc.date.available | 2021-08-11T08:40:33Z | - |
dc.date.issued | 2020 | - |
dc.identifier.issn | 1975-5171 | - |
dc.identifier.issn | 2383-7977 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/3389 | - |
dc.description.abstract | Background: Lightwand is a convenient tool that can be used instead of a laryngoscope for intubation. Tracheal intubation causes direct stimulation of the larynx, drastically increasing hemodynamic values including blood pressure and heart rate. This study aims to identify the effect of different doses of esmolol on hemodynamic changes during lightwand intubation.Methods: The study subjects included 140 patients who underwent general anesthesia for elective surgery. The patients were randomly divided into four groups (35 patients in each group). The ‘C’ group only received 20 ml of normal saline, while the ‘E0.5’, ‘E1’, and ‘E2’ groups received 20 ml of normal saline containing esmolol—0.5 mg/kg, 1 mg/kg, and 2 mg/kg, respectively, injected 2 min prior to intubation. The patients’ blood pressure, heart rate, and rate-pressure product were measured six times, before and after the intubation.Results: The degree of heart rate elevation was suppressed in the E1 and E2 groups compared to the C group, and RPP after intubation significantly decreased in the E2 group compared to the C group.Conclusions: 1–2 mg/kg of a single esmolol injection prior to lightwand intubation effectively blunts heart rate elevation, and 2 mg/kg of esmolol injection blunts rate-pressure product elevation. | - |
dc.format.extent | 7 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | 대한마취통증의학회 | - |
dc.title | Dosing study of esmolol for reducing hemodynamic changes during lightwand intubation | - |
dc.title.alternative | Dosing study of esmolol for reducing hemodynamic changes during lightwand intubation | - |
dc.type | Article | - |
dc.publisher.location | 대한민국 | - |
dc.identifier.doi | 10.17085/apm.19067 | - |
dc.identifier.bibliographicCitation | Anesthesia and Pain Medicine, v.15, no.4, pp 417 - 423 | - |
dc.citation.title | Anesthesia and Pain Medicine | - |
dc.citation.volume | 15 | - |
dc.citation.number | 4 | - |
dc.citation.startPage | 417 | - |
dc.citation.endPage | 423 | - |
dc.identifier.kciid | ART002640143 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | kci | - |
dc.subject.keywordAuthor | Blood pressure | - |
dc.subject.keywordAuthor | Esmolol | - |
dc.subject.keywordAuthor | Heart rate | - |
dc.subject.keywordAuthor | Intubation | - |
dc.subject.keywordAuthor | Lightwand | - |
dc.subject.keywordAuthor | Rate pressure product. | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(31538) 22, Soonchunhyang-ro, Asan-si, Chungcheongnam-do, Republic of Korea+82-41-530-1114
COPYRIGHT 2021 by SOONCHUNHYANG UNIVERSITY ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.