Detailed Information

Cited 0 time in webofscience Cited 4 time in scopus
Metadata Downloads

Surgical Treatment of Mandible Fracture Using Unsintered Hydroxyapatite/Poly L-Lactide Composite Fixation System

Authors
Lee, Sun JaePark, Eun SooNam, Seung MinChoi, Chang YongShin, Ho SungKim, Yong Bae
Issue Date
Nov-2019
Publisher
Lippincott Williams & Wilkins Ltd.
Keywords
Fracture fixation internal; hydroxyapatite-polylactide; mandibular fractures
Citation
Journal of Craniofacial Surgery, v.30, no.8, pp 2573 - 2575
Pages
3
Journal Title
Journal of Craniofacial Surgery
Volume
30
Number
8
Start Page
2573
End Page
2575
URI
https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/4092
DOI
10.1097/SCS.0000000000006030
ISSN
1049-2275
1536-3732
Abstract
Recently, absorbable plates have been used for various types of facial fractures. However, in the case of mandibular fractures, a large amount of force is applied after fixation. Thus, a firm fixation is necessary. In particular, unfavorable fractures are more frequent in mandibular fractures. Therefore, plates should be strong enough to withstand forces at the time of surgery. The purpose of this study was to determine clinical efficacy and usefulness of unsintered hydroxyapatite (u-HA)/poly (L-lactide) (PLLA) composite system by clinical application and follow-up of fixation in patients with mandible fracture. A total of 13 patients with mandible fractures were assessed for compliance with the selection criteria. Fracture site was confirmed with radiographic findings including X-ray and facial computed tomography images. Subjects who fulfilled all criteria underwent operation using HA/PLLA composite fixation system (OSTEOTRANS; Takiron Co Ltd, Osaka, Japan). After reduction of fracture site through oral or skin incision, we placed OSTEOTRANS plates on fracture line and performed rigid fixation with OSTEOTRANS-MX screws. Followup was performed at 1 week, 1, 3, and 6 months after surgery. Occlusion and mouth opening were checked by physical examination and radiographic finding. We also confirmed bone approximation status, bony gap change, and bone union status. All patients finished every follow-up. They were satisfied with outcomes without complications such as malocclusion, foreign body sensation, or tenderness. This study confirms that OSTEOTRANS can be used appropriately for mandibular fractures.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Plastic Surgery > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Choi, Chang yong photo

Choi, Chang yong
College of Medicine (Department of Plastic Surgery)
Read more

Altmetrics

Total Views & Downloads

BROWSE