Detailed Information

Cited 0 time in webofscience Cited 3 time in scopus
Metadata Downloads

Metallic Press-fit Radial Head Replacement for Radial Head Fractures

Authors
Jung, Ki JinNho, Jae-HwiWang, Soon-DoHong, Yong CheolKim, Byung Sung
Issue Date
Nov-2019
Publisher
Slack, Inc.
Keywords
Radial Head Fracture
Citation
Orthopedics, v.42, no.6, pp E545 - E551
Journal Title
Orthopedics
Volume
42
Number
6
Start Page
E545
End Page
E551
URI
https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/4107
DOI
10.3928/01477447-20190604-07
ISSN
0147-7447
1938-2367
Abstract
This study evaluated the clinical and radiographic results of patients who sustained nonreconstructible radial head fractures that subsequently were treated with a metallic press-fit radial head prosthesis (RHP). Nine patients with comminuted radial head fractures were treated with a metallic press-fit RHP; mean follow-up was 38.7 months. The radial head fracture was acute in 6 patients (group A) and chronic in 3 patients (group 13). Functional evaluation was assessed using the Mayo Elbow Performance Score (MEPS) and Disabilities of the Arm, Shoulder and Hand (DASH) Questionnaire. Radiographs were assessed for loosening, radiocapitellar alignment, osteolysis of the radial neck, lucency, periarticular ossifications, and ulnohumeral degeneration. Average flexion and flexion contracture were 133 degrees and 5 degrees, respectively. Average supination and pronation angles were 70 degrees and 73 degrees, respectively. Wan MEPS was 90 (range, 70-100), and elbow performance was excellent in 4 patients, good in 4 patients, and fair in 1 patient. Mean DASH score was 21.9 (range, 0-61). Flexion contracture, forearm rotation arc, and MEPS score were better and the complication rate was lower in group A compared with group B. Centering of the stem was observed on both anteroposterior and lateral radiographs in 6 patients. Lucent lines around the prostheses, stress shielding under the neck of the radius, and ectopic ossification occurred in 5 patients. Three patients had osteoarthritis. Elbow stiffness and ulnar impaction syndrome occurred in 2 patients but only after placement of a secondary RHP. Satisfactory outcomes were obtained using a metallic press-fit RHP for nonreconstructible radial head fractures.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Orthopedic Surgery > 1. Journal Articles
College of Medicine > Department of Orthopedic Surgery > 1. Journal Articles
College of Medicine > Department of Orthopedic Surgery > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Byung Sung photo

Kim, Byung Sung
College of Medicine (Department of Orthopedic Surgery)
Read more

Altmetrics

Total Views & Downloads

BROWSE