Detailed Information

Cited 0 time in webofscience Cited 14 time in scopus
Metadata Downloads

Reliability of Korean Triage and Acuity Scale: Interrater Agreement between Two Experienced Nurses by Real-Time Triage and Analysis of Influencing Factors to Disagreement of Triage Levelsopen access

Authors
Park, Joon BumLee, JuncheolKim, Yu JinLee, Jin HeeLim, Tae Ho
Issue Date
22-Jul-2019
Publisher
대한의학회
Keywords
Reliability; Triage; Emergency Department
Citation
Journal of Korean Medical Science, v.34, no.28
Journal Title
Journal of Korean Medical Science
Volume
34
Number
28
URI
https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/4378
DOI
10.3346/jkms.2019.34.e189
ISSN
1011-8934
1598-6357
Abstract
Background: All emergency centers in Korea use the Korean Triage and Acuity Scale (KTAS) as their initial triage tool. However, KTAS has been used without verification of its reliability. In this study, we assess the interrater agreement of KTAS by two independent nurses in real-time and analyse the factors which have an effect on the disagreement of KTAS levels. Methods: This study was a prospective observational study conducted with patients who visited an emergency department (ED). Two teams, each composed of two nurses, triaged patients and recorded KTAS level and the main complaint from the list of167 KTAS complaints, as well as modifiers. Interrater reliability between the two nurses in each team was assessed by weighted-kappa. Pearson's chi(2) test was conducted to determine if there were differences between each nurse's KTAS levels, depending on whether they chose the same complaints and the same modifiers or not. Results: The two teams triaged a total of 1,998 patients who visited the Ell. Weighted-kappa value was 0.772 (95% confidence interval [CI], 0.750-0.794). Patients triaged by different chosen complaints showed (38.0%) higher inconsistency rate in KTAS levels than those triaged by the same complaint (10.9%, P< 0.001). When nurses chose the same complaint and different modifiers, the ratio of different levels (50.5%) was higher than that of the same complaint and same modifier (8.1%, P< 0.001). Conclusion: This study showed that KTAS is a reliable tool. Selected complaints and modifiers are confirmed as important factors for reliability; therefore, selecting them properly should be emphasized during KTAS training courses.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Emergency Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Joon Bum photo

Park, Joon Bum
College of Medicine (Department of Emergency Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE