Dual-Energy and Iterative Metal Artifact Reduction for Reducing Artifacts Due to Metallic Hardware: A Loosening Hip Phantom Study
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Yeun Jeong | - |
dc.contributor.author | Cha, Jang Gyu | - |
dc.contributor.author | Kim, Hunji | - |
dc.contributor.author | Yi, Ji Sook | - |
dc.contributor.author | Kim, Hyun-Joo | - |
dc.date.accessioned | 2021-08-11T09:44:09Z | - |
dc.date.available | 2021-08-11T09:44:09Z | - |
dc.date.issued | 2019-05 | - |
dc.identifier.issn | 0361-803X | - |
dc.identifier.issn | 1546-3141 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/4568 | - |
dc.description.abstract | OBJECTIVE. The purpose of this study was to compare the value of iterative metal artifact reduction (IMAR) with that of dual-energy CT (DECT) and filtered back projection (FBP) CT protocols for reducing metal artifacts and for facilitating visualization of the acetabular cortex in a loosening hip phantom model. MATERIALS AND METHODS. CT scans were obtained with conventional FBP and dual-source CT for two types of hip phantom. For the quantitative study, attenuation was measured by placement of ROIs in the phantoms around the metallic hardware. The differences between mean attenuation in each ROI and the actual attenuation were compared among the three CT protocols. For the qualitative study, the visibility of the acetabular cortex in the artificial loosening area of the total hip arthroplasty model and in the joint space of the bipolar hemiarthroplasty model was evaluated by measurement of the obscured cortical angle. RESULTS. In the quantitative study, attenuation differences in the bipolar hemiarthroplasty model were markedly decreased with IMAR and DECT compared with FBP (p = 0.006-0.007). In the total hip replacement model, attenuation differences were significantly lower with IMAR than with FBP (p < 0.001). In the qualitative study, visibility of the acetabular cortex was markedly improved with IMAR compared with DECT and FBP (p < 0.001) for both hip models. CONCLUSION. CT with IMAR can reduce the distortion caused by metal artifacts more effectively than FBP and DECT can while preserving visibility of the acetabular cortex in both bipolar hemiarthroplasty and total hip arthroplasty phantoms. | - |
dc.format.extent | 6 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | American Roentgen Ray Society | - |
dc.title | Dual-Energy and Iterative Metal Artifact Reduction for Reducing Artifacts Due to Metallic Hardware: A Loosening Hip Phantom Study | - |
dc.type | Article | - |
dc.publisher.location | 미국 | - |
dc.identifier.doi | 10.2214/AJR.18.20413 | - |
dc.identifier.scopusid | 2-s2.0-85065655900 | - |
dc.identifier.wosid | 000465359600029 | - |
dc.identifier.bibliographicCitation | American Journal of Roentgenology, v.212, no.5, pp 1106 - 1111 | - |
dc.citation.title | American Journal of Roentgenology | - |
dc.citation.volume | 212 | - |
dc.citation.number | 5 | - |
dc.citation.startPage | 1106 | - |
dc.citation.endPage | 1111 | - |
dc.type.docType | Article | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | sci | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.subject.keywordPlus | CT | - |
dc.subject.keywordPlus | RECONSTRUCTION | - |
dc.subject.keywordAuthor | CT | - |
dc.subject.keywordAuthor | hip joint | - |
dc.subject.keywordAuthor | metallic artifacts | - |
dc.subject.keywordAuthor | postoperative imaging | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(31538) 22, Soonchunhyang-ro, Asan-si, Chungcheongnam-do, Republic of Korea+82-41-530-1114
COPYRIGHT 2021 by SOONCHUNHYANG UNIVERSITY ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.