Detailed Information

Cited 0 time in webofscience Cited 25 time in scopus
Metadata Downloads

Dual-Energy and Iterative Metal Artifact Reduction for Reducing Artifacts Due to Metallic Hardware: A Loosening Hip Phantom Study

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Yeun Jeong-
dc.contributor.authorCha, Jang Gyu-
dc.contributor.authorKim, Hunji-
dc.contributor.authorYi, Ji Sook-
dc.contributor.authorKim, Hyun-Joo-
dc.date.accessioned2021-08-11T09:44:09Z-
dc.date.available2021-08-11T09:44:09Z-
dc.date.issued2019-05-
dc.identifier.issn0361-803X-
dc.identifier.issn1546-3141-
dc.identifier.urihttps://scholarworks.bwise.kr/sch/handle/2021.sw.sch/4568-
dc.description.abstractOBJECTIVE. The purpose of this study was to compare the value of iterative metal artifact reduction (IMAR) with that of dual-energy CT (DECT) and filtered back projection (FBP) CT protocols for reducing metal artifacts and for facilitating visualization of the acetabular cortex in a loosening hip phantom model. MATERIALS AND METHODS. CT scans were obtained with conventional FBP and dual-source CT for two types of hip phantom. For the quantitative study, attenuation was measured by placement of ROIs in the phantoms around the metallic hardware. The differences between mean attenuation in each ROI and the actual attenuation were compared among the three CT protocols. For the qualitative study, the visibility of the acetabular cortex in the artificial loosening area of the total hip arthroplasty model and in the joint space of the bipolar hemiarthroplasty model was evaluated by measurement of the obscured cortical angle. RESULTS. In the quantitative study, attenuation differences in the bipolar hemiarthroplasty model were markedly decreased with IMAR and DECT compared with FBP (p = 0.006-0.007). In the total hip replacement model, attenuation differences were significantly lower with IMAR than with FBP (p < 0.001). In the qualitative study, visibility of the acetabular cortex was markedly improved with IMAR compared with DECT and FBP (p < 0.001) for both hip models. CONCLUSION. CT with IMAR can reduce the distortion caused by metal artifacts more effectively than FBP and DECT can while preserving visibility of the acetabular cortex in both bipolar hemiarthroplasty and total hip arthroplasty phantoms.-
dc.format.extent6-
dc.language영어-
dc.language.isoENG-
dc.publisherAmerican Roentgen Ray Society-
dc.titleDual-Energy and Iterative Metal Artifact Reduction for Reducing Artifacts Due to Metallic Hardware: A Loosening Hip Phantom Study-
dc.typeArticle-
dc.publisher.location미국-
dc.identifier.doi10.2214/AJR.18.20413-
dc.identifier.scopusid2-s2.0-85065655900-
dc.identifier.wosid000465359600029-
dc.identifier.bibliographicCitationAmerican Journal of Roentgenology, v.212, no.5, pp 1106 - 1111-
dc.citation.titleAmerican Journal of Roentgenology-
dc.citation.volume212-
dc.citation.number5-
dc.citation.startPage1106-
dc.citation.endPage1111-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasssci-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.subject.keywordPlusCT-
dc.subject.keywordPlusRECONSTRUCTION-
dc.subject.keywordAuthorCT-
dc.subject.keywordAuthorhip joint-
dc.subject.keywordAuthormetallic artifacts-
dc.subject.keywordAuthorpostoperative imaging-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Radiology > 1. Journal Articles
College of Medicine > Department of Radiology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Cha, Jang Gyu photo

Cha, Jang Gyu
College of Medicine (Department of Radiology)
Read more

Altmetrics

Total Views & Downloads

BROWSE