Detailed Information

Cited 0 time in webofscience Cited 13 time in scopus
Metadata Downloads

An integrated ion-selective optode sensor cartridge for directly detecting electrolyte ions in blood plasma without pretreatment to adjust pH

Full metadata record
DC Field Value Language
dc.contributor.authorLee, Joonhyung-
dc.contributor.authorHahn, Young Ki-
dc.contributor.authorPark, Jin-Young-
dc.contributor.authorSeo, Hyejung-
dc.contributor.authorJung, Jaeyeon-
dc.contributor.authorCho, Euyhyun-
dc.contributor.authorChoi, Youn-Suk-
dc.contributor.authorLee, Soo Suk-
dc.date.accessioned2021-08-11T10:23:43Z-
dc.date.available2021-08-11T10:23:43Z-
dc.date.issued2019-02-01-
dc.identifier.issn0925-4005-
dc.identifier.urihttps://scholarworks.bwise.kr/sch/handle/2021.sw.sch/4733-
dc.description.abstractWe present a new integrated optode sensor cartridge that directly detects potassium, sodium, and chloride ions in blood plasma without pretreatment to adjust pH. Each optode sensor mainly consists of two separate layers, the optode and a dried buffer, which work by introducing plasma without blood cells filtered by a membrane filter. The optode layer uses a neutral ion-selective optode that is composed of an ionophore, a pH indicator dye (chromoionophore), and ionic additives incorporated in a plasticized polyvinyl chloride membrane. The dried buffer layer, which dissolves on contact with plasma, is applied to the optode layer, resulting in the constant pH of the plasma within the optode membrane. We determined the pHs of each dried buffer (potassium, sodium, and chloride) layer to be 7.0, 6.0, and 4.5, respectively, based on the pK(a) of their corresponding chromoionophores and effective buffer ranges. Consequently, the sensor responses varied as a function of the potassium, sodium, and chloride ion concentrations. To validate the accuracy of the ion-selective optode sensors, we investigated the correlations of potassium, sodium, and chloride ion concentrations with a commercial system (cobas (R) 8000) and observed comparable agreement between the two systems with correlation coefficients of 0.976, 0.955, and 0.966, respectively.-
dc.format.extent7-
dc.language영어-
dc.language.isoENG-
dc.publisherElsevier BV-
dc.titleAn integrated ion-selective optode sensor cartridge for directly detecting electrolyte ions in blood plasma without pretreatment to adjust pH-
dc.typeArticle-
dc.publisher.location스위스-
dc.identifier.doi10.1016/j.snb.2018.10.067-
dc.identifier.scopusid2-s2.0-85055083936-
dc.identifier.wosid000450302300032-
dc.identifier.bibliographicCitationSensors and Actuators, B: Chemical, v.280, pp 256 - 262-
dc.citation.titleSensors and Actuators, B: Chemical-
dc.citation.volume280-
dc.citation.startPage256-
dc.citation.endPage262-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasssci-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalResearchAreaElectrochemistry-
dc.relation.journalResearchAreaInstruments & Instrumentation-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.relation.journalWebOfScienceCategoryElectrochemistry-
dc.relation.journalWebOfScienceCategoryInstruments & Instrumentation-
dc.subject.keywordPlusLIPOPHILIC ANIONIC DYE-
dc.subject.keywordPlusFILM OPTODES-
dc.subject.keywordPlusCHLORIDE-
dc.subject.keywordPlusPOTASSIUM-
dc.subject.keywordPlusSERUM-
dc.subject.keywordPlusIONOPHORES-
dc.subject.keywordPlusLIFETIME-
dc.subject.keywordPlusURINE-
dc.subject.keywordPlusASSAY-
dc.subject.keywordAuthorIon-selective optode-
dc.subject.keywordAuthorIonophore-
dc.subject.keywordAuthorChromoionophore-
dc.subject.keywordAuthorElectrolytes-
dc.subject.keywordAuthorCartridge-
dc.subject.keywordAuthorAbsorbance-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medical Sciences > Department of Pharmaceutical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Soo Suk photo

Lee, Soo Suk
College of Medical Sciences (Department of Pharmaceutical Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE