Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

On-demand Microfluidic Manipulation of Thermally Stable Water-in-Perfluorocarbon Emulsions

Full metadata record
DC Field Value Language
dc.contributor.authorJang, Mun-Bae-
dc.contributor.authorMoon, Taewoo-
dc.contributor.authorChoi, Jae-Hoon-
dc.contributor.authorChung, Sung-Hee-
dc.contributor.authorHa, Jong-Wook-
dc.contributor.authorLim, Jong-Min-
dc.contributor.authorLee, Seung-Kon-
dc.contributor.authorYang, Seung-Man-
dc.contributor.authorYoum, Kyung-Ho-
dc.contributor.authorShin, Kwanwoo-
dc.contributor.authorYi, Gi-Ra-
dc.date.accessioned2021-08-11T11:23:57Z-
dc.date.available2021-08-11T11:23:57Z-
dc.date.issued2018-12-
dc.identifier.issn1598-5032-
dc.identifier.issn2092-7673-
dc.identifier.urihttps://scholarworks.bwise.kr/sch/handle/2021.sw.sch/5448-
dc.description.abstractMonodispersed thermally stable aqueous emulsions were generated in perfluorocarbon oil with penta-block copolymers of fluorocarbon and poly(ethylene oxide-b-propylene oxide-b-ethylene oxide), which are controlled in guided channels of microfluidic devices, which were essentially the protrusion on top of microfluidic channels. Aqueous emulsions could stably follow the guide channels and sequentially stored at dead ends of guide channels. Depending on the size ratio of emulsion to trapping region, one or two emulsions were stored in two-dimensional arrays on demand. By adding pneumatic valve actuators on top of guide channel, they could be stored or released on demand or as programmed. Furthermore, by encapsulating colloidal particles and Hela cells in the thermally stable water-in-perfluorocarbon emulsions, we demonstrated that particle-laden and cellladen emulsions could be manipulated in controlled and programmed manner.-
dc.format.extent7-
dc.language영어-
dc.language.isoENG-
dc.publisher한국고분자학회-
dc.titleOn-demand Microfluidic Manipulation of Thermally Stable Water-in-Perfluorocarbon Emulsions-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.doi10.1007/s13233-018-6144-7-
dc.identifier.scopusid2-s2.0-85055874849-
dc.identifier.wosid000454529200016-
dc.identifier.bibliographicCitationMacromolecular Research, v.26, no.12, pp 1160 - 1166-
dc.citation.titleMacromolecular Research-
dc.citation.volume26-
dc.citation.number12-
dc.citation.startPage1160-
dc.citation.endPage1166-
dc.type.docTypeArticle-
dc.identifier.kciidART002415370-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasssci-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaPolymer Science-
dc.relation.journalWebOfScienceCategoryPolymer Science-
dc.subject.keywordAuthormicrofluidic chip-
dc.subject.keywordAuthoremulsions-
dc.subject.keywordAuthorpneumatic valves-
dc.subject.keywordAuthoron-demand manipulation-
dc.subject.keywordAuthorhela cells-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Chemical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lim, Jong Min photo

Lim, Jong Min
College of Engineering (Department of Chemical Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE