Detailed Information

Cited 0 time in webofscience Cited 5 time in scopus
Metadata Downloads

Sweating distribution and active sweat glands on the scalp of young males in hot-dry and hot-humid environments

Authors
Jung, DaheeKim, Yung-BinLee, Jeong-BeomMuhamed, Ahmad Munir CheLee, Joo-Young
Issue Date
Dec-2018
Publisher
Springer Verlag
Keywords
Sweating; Sweat distribution; Active sweat glands; Non-hairy head; Air humidity; Total sweat rate
Citation
European Journal of Applied Physiology, v.118, no.12, pp 2655 - 2667
Pages
13
Journal Title
European Journal of Applied Physiology
Volume
118
Number
12
Start Page
2655
End Page
2667
URI
https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/5468
DOI
10.1007/s00421-018-3988-7
ISSN
1439-6319
1439-6327
Abstract
PurposeWe investigated the effects of humidity on regional sweating secretion and active sweat gland density on the scalp during passive heating in hot environments.MethodsEight male subjects shaved their heads prior to expose to dry (30%RH; H30%) and humid (85%RH; H85%) conditions at an air temperature of 32 degrees C. Total sweat rate, local sweat rates (frontal, vertex, temporal, and occipital regions), active sweat glands on the scalp (2 frontal, 2 parietal, 2 temporal, 1 occipital, and 1 vertex), and rectal and skin temperatures were measured during leg immersion in 42 degrees C water for 60min.Results(1) Total sweat rates were greater for H30% (179.435.6gh(-1)) than for H85% (148.1 +/- 27.2gh(-1)) (P<0.05). (2) Scalp sweat secretion tended to be greater in the H85% than the H30%. (3) Head sweat rates were greater on the frontal than on the vertex for both humidity conditions (P<0.05). (4) Active sweat gland density on the scalp was greater for H85% (82 +/- 13glandscm(-2)) than for H30% (62 +/- 17glandscm(-2)) (P<0.05). (5) No significant difference was found in rectal temperature between H30% and H85%, whereas mean skin temperature was significantly lower for H30% (34.8 +/- 0.7 degrees C) than for the H85% condition (36.0 +/- 0.3 degrees C) (P<0.05).Conclusions These results indicate that the thermoregulatory sweating responses for the scalp region were significantly increased in the hot-humid condition compared to the hot-dry condition. Among the regions on the scalp surface, the vertex was the least sensitive to the change in humidity.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Physiology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, jeong beom photo

Lee, jeong beom
College of Medicine (Department of Physiology)
Read more

Altmetrics

Total Views & Downloads

BROWSE