Development of A Textile Capacitive Proximity Sensor and Gait Monitoring System for Smart Healthcare
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Min, Se Dong | - |
dc.contributor.author | Wang, Changwon | - |
dc.contributor.author | Park, Doo-Soon | - |
dc.contributor.author | Park, Jong Hyuk | - |
dc.date.accessioned | 2021-08-11T12:24:17Z | - |
dc.date.available | 2021-08-11T12:24:17Z | - |
dc.date.issued | 2018-04 | - |
dc.identifier.issn | 0148-5598 | - |
dc.identifier.issn | 1573-689X | - |
dc.identifier.uri | https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/6088 | - |
dc.description.abstract | Gait is not only one of the most important functions and activities in daily life but is also a parameter to monitor one's health status. We propose a single channel capacitive proximity pressure sensor (TCPS) and gait monitoring system for smart healthcare. Insole-type TCPS (270 mm in length) was designed consisting of three layers including two shield layers and a sensor layer. Analyzing the step count and stride time are the basic indicators in gait analysis, thus they were selected as evaluation indicators. A total of 12 subjects participated in the experiment to evaluate the resolution of our TCPS. To evaluate the accuracy of TCPS, step count and its error rates were simultaneously detected by naked eye, ZIKTO Walk (ZIKTO Co., Korea), and HJ-203-K pedometer (Omron Co., Japan) as reference. Results showed that the error rate of 1.77% in TCPS was lower than those of other devices and correlation coefficient was 0.958 (p-value = 0.000). ZIKTO Walk and pedometer do not provide information on stride time, therefore it was detected by F-scan (Tekscan, USA) to evaluate the performance of TCPS. As a result, error rate of stride time measured by TCPS was found to be 1% and the correlation coefficient was 0.685 (p-value = 0.000). According to these results, our proposed system may be helpful in development of gait monitoring and measurement system as smart healthcare. | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | Kluwer Academic/Plenum Publishers | - |
dc.title | Development of A Textile Capacitive Proximity Sensor and Gait Monitoring System for Smart Healthcare | - |
dc.type | Article | - |
dc.publisher.location | 미국 | - |
dc.identifier.doi | 10.1007/s10916-018-0928-3 | - |
dc.identifier.scopusid | 2-s2.0-85043978721 | - |
dc.identifier.wosid | 000428337000019 | - |
dc.identifier.bibliographicCitation | Journal of Medical Systems, v.42, no.4 | - |
dc.citation.title | Journal of Medical Systems | - |
dc.citation.volume | 42 | - |
dc.citation.number | 4 | - |
dc.type.docType | Article | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Health Care Sciences & Services | - |
dc.relation.journalResearchArea | Medical Informatics | - |
dc.relation.journalWebOfScienceCategory | Health Care Sciences & Services | - |
dc.relation.journalWebOfScienceCategory | Medical Informatics | - |
dc.subject.keywordPlus | PRESSURE SENSOR | - |
dc.subject.keywordPlus | BILATERAL COORDINATION | - |
dc.subject.keywordPlus | BIG DATA | - |
dc.subject.keywordPlus | RECOGNITION | - |
dc.subject.keywordAuthor | Gait | - |
dc.subject.keywordAuthor | Situation | - |
dc.subject.keywordAuthor | Smart Healthcare | - |
dc.subject.keywordAuthor | Capacitive Proximity Sensor | - |
dc.subject.keywordAuthor | Conductive Textile | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(31538) 22, Soonchunhyang-ro, Asan-si, Chungcheongnam-do, Republic of Korea+82-41-530-1114
COPYRIGHT 2021 by SOONCHUNHYANG UNIVERSITY ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.