Focal Increased Tc-99m MDP Uptake in the Nutrient Foramen of the Femoral Diaphysis on Bone SPECT/CT
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Cha, Hwajin | - |
dc.contributor.author | Park, Soo Bin | - |
dc.contributor.author | Kim, Hyun-joo | - |
dc.date.accessioned | 2021-08-11T12:24:18Z | - |
dc.date.available | 2021-08-11T12:24:18Z | - |
dc.date.issued | 2018-04 | - |
dc.identifier.issn | 1869-3474 | - |
dc.identifier.issn | 1869-3482 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/6093 | - |
dc.description.abstract | We present images of an 83-year-old female with a history of osteoporosis and bilateral total knee replacement arthroplasty, referred for bone scintigraphy and single-photon emission computed tomography (SPECT)/computed tomography (CT), owing to left knee pain. No trauma to, or intense exercise of, the knee was reported. The bone scan and SPECT/CT revealed a focally increased Tc-99m methylene diphosphonate (MDP) uptake in the medial cortex of the left femoral diaphysis with matched linear radiolucency on CT images. This was misinterpreted as atypical femoral stress fracture; however, focal stress reaction injury to the nutrient foramen was confirmed on contrast-enhanced magnetic resonance imaging. | - |
dc.format.extent | 4 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | 대한핵의학회 | - |
dc.title | Focal Increased Tc-99m MDP Uptake in the Nutrient Foramen of the Femoral Diaphysis on Bone SPECT/CT | - |
dc.type | Article | - |
dc.publisher.location | 대한민국 | - |
dc.identifier.doi | 10.1007/s13139-017-0489-2 | - |
dc.identifier.scopusid | 2-s2.0-85045398148 | - |
dc.identifier.wosid | 000429971000012 | - |
dc.identifier.bibliographicCitation | Nuclear Medicine and Molecular Imaging, v.52, no.2, pp 162 - 165 | - |
dc.citation.title | Nuclear Medicine and Molecular Imaging | - |
dc.citation.volume | 52 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 162 | - |
dc.citation.endPage | 165 | - |
dc.type.docType | Editorial Material | - |
dc.identifier.kciid | ART002337399 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | esci | - |
dc.description.journalRegisteredClass | kci | - |
dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.subject.keywordAuthor | Tc-99mMDP | - |
dc.subject.keywordAuthor | Bone scan | - |
dc.subject.keywordAuthor | SPECT | - |
dc.subject.keywordAuthor | SPECT/CT | - |
dc.subject.keywordAuthor | Nutrient foramen | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(31538) 22, Soonchunhyang-ro, Asan-si, Chungcheongnam-do, Republic of Korea+82-41-530-1114
COPYRIGHT 2021 by SOONCHUNHYANG UNIVERSITY ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.