Detailed Information

Cited 0 time in webofscience Cited 1 time in scopus
Metadata Downloads

Treatment Planning Volume According to Change in Bladder Volume in Therapy of Proton Beam in Magnetic Field

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Sun-young-
dc.contributor.authorLee, Hae-Kag-
dc.contributor.authorJu, Myung-Sik-
dc.contributor.authorJoo, Sun-Hyung-
dc.contributor.authorCho, Jae-Hwan-
dc.date.accessioned2021-08-11T14:23:44Z-
dc.date.available2021-08-11T14:23:44Z-
dc.date.issued2017-12-
dc.identifier.issn1226-1750-
dc.identifier.issn2233-6656-
dc.identifier.urihttps://scholarworks.bwise.kr/sch/handle/2021.sw.sch/6996-
dc.description.abstractThe purpose of this study was to investigate the changes of bladder volume before therapy of proton beam in magnetic field, and to estimate the target volume (PTV) margin to be considered in treatment planning. Thirty patients with prostate cancer were included in this study. Three gold fiducial markers were attached to the prostate to confirm the position of the prostate by pretreatment X-ray. The urine was completely emptied 1 hour and 30 minutes before the CT-Simulation, and the urine was confirmed by ultrasonography. The bladder was filled with 500 cc of water. Bladder volume was measured by CT scans after treatment. On the first day of treatment, 30 patients underwent the same pretreatment as in CT-Simulation, and their bladder volume was obtained using ultrasound during the 25th treatment, and compared with the treatment plan. We also investigated daytime volatility during the treatment period. The mean bladder volume ultrasonography mean (BVUSmean) was found to be 302 +/- 89 ml (range: 168 +/- 166 ml)-553 ml). BVUSmean was 84 A) of BVCTmean Ultra-sound-measured bladder volume was smaller than that measured by CT. The correlation coefficient between BVUSmean and BVcrmean was 0.187 (p = 0.322). Bland-Altman analysis showed that the BVCTmean and BV(USmean)agreement ranged from-202.17 to 315.83, with an average value of 70. The mean (bias, bias) and standard deviation (precision) of the differences between the two measurements was 56.83 +/- 132.14 ml. BVCTmean and BVUSmean showed a large range of change. BVUSweekly1-5, which was measured Weeklyly, showed a certain decrease with the treatment time, as compared with (CTmean) In conclusion, large changes and differences in bladder volume should always be treated with ultrasound before treatment, and the range of rectal area should coincide. Therefore, excessive radiography is unnecessary.-
dc.format.extent6-
dc.language영어-
dc.language.isoENG-
dc.publisher한국자기학회-
dc.titleTreatment Planning Volume According to Change in Bladder Volume in Therapy of Proton Beam in Magnetic Field-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.doi10.4283/JMAG.2017.22.4.665-
dc.identifier.scopusid2-s2.0-85040092449-
dc.identifier.wosid000419081900020-
dc.identifier.bibliographicCitationJournal of Magnetics, v.22, no.4, pp 665 - 670-
dc.citation.titleJournal of Magnetics-
dc.citation.volume22-
dc.citation.number4-
dc.citation.startPage665-
dc.citation.endPage670-
dc.type.docTypeArticle-
dc.identifier.kciidART002303573-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaMaterials Science-
dc.relation.journalResearchAreaPhysics-
dc.relation.journalWebOfScienceCategoryMaterials Science, Multidisciplinary-
dc.relation.journalWebOfScienceCategoryPhysics, Applied-
dc.relation.journalWebOfScienceCategoryPhysics, Condensed Matter-
dc.subject.keywordPlusMODULATED RADIATION-THERAPY-
dc.subject.keywordPlusPROSTATE-CANCER-
dc.subject.keywordPlusCONFORMAL RADIOTHERAPY-
dc.subject.keywordPlusTOXICITY-
dc.subject.keywordPlusULTRASONOGRAPHY-
dc.subject.keywordPlusACCURACY-
dc.subject.keywordPlusRECTUM-
dc.subject.keywordAuthorproton beam in magnetic field-
dc.subject.keywordAuthorPlanning Target Volume (PTV) margin-
dc.subject.keywordAuthorrectal balloon-
dc.subject.keywordAuthorBVCTmean-
dc.subject.keywordAuthorBVUSmean-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Computer Science and Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, HAE KAG photo

Lee, HAE KAG
College of Engineering (Department of Computer Science and Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE