Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Relevant Reduction Effect with a Modified Thermoplastic Mask of Rotational Error for Glottic Cancer in IMRT

Full metadata record
DC Field Value Language
dc.contributor.authorJung, Jae Hong-
dc.contributor.authorJung, Joo-Young-
dc.contributor.authorCho, Kwang Hwan-
dc.contributor.authorRyu, Mi Ryeong-
dc.contributor.authorBae, Sun Hyun-
dc.contributor.authorMoon, Seong Kwon-
dc.contributor.authorKim, Yong Ho-
dc.contributor.authorChoe, Bo-Young-
dc.contributor.authorSuh, Tae Suk-
dc.date.accessioned2021-08-11T15:24:29Z-
dc.date.available2021-08-11T15:24:29Z-
dc.date.issued2017-02-
dc.identifier.issn0374-4884-
dc.identifier.issn1976-8524-
dc.identifier.urihttps://scholarworks.bwise.kr/sch/handle/2021.sw.sch/7807-
dc.description.abstractThe purpose of this study was to analyze the glottis rotational error (GRE) by using a thermoplastic mask for patients with the glottic cancer undergoing intensity-modulated radiation therapy (IMRT). We selected 20 patients with glottic cancer who had received IMRT by using the tomotherapy. The image modalities with both kilovoltage computed tomography (planning kVCT) and megavoltage CT (daily MVCT) images were used for evaluating the error. Six anatomical landmarks in the image were defined to evaluate a correlation between the absolute GRE (.) and the length of contact with the underlying skin of the patient by the mask (mask, mm). We also statistically analyzed the results by using the Pearson's correlation coefficient and a linear regression analysis (P < 0.05). The mask and the absolute GRE were verified to have a statistical correlation (P < 0.01). We found a statistical significance for each parameter in the linear regression analysis (mask versus absolute roll: P = 0.004 [ P < 0.05]; mask versus 3D-error: P = 0.000 [P < 0.05]). The range of the 3D-errors with contact by the mask was from 1.2% -39.7% between the maximumand no-contact case in this study. A thermoplastic mask with a tight, increased contact area may possibly contribute to the uncertainty of the reproducibility as a variation of the absolute GRE. Thus, we suggest that a modified mask, such as one that covers only the glottis area, can significantly reduce the patients' setup errors during the treatment.-
dc.format.extent9-
dc.language영어-
dc.language.isoENG-
dc.publisher한국물리학회-
dc.titleRelevant Reduction Effect with a Modified Thermoplastic Mask of Rotational Error for Glottic Cancer in IMRT-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.doi10.3938/jkps.70.308-
dc.identifier.scopusid2-s2.0-85012000517-
dc.identifier.wosid000396206800013-
dc.identifier.bibliographicCitationJournal of the Korean Physical Society, v.70, no.3, pp 308 - 316-
dc.citation.titleJournal of the Korean Physical Society-
dc.citation.volume70-
dc.citation.number3-
dc.citation.startPage308-
dc.citation.endPage316-
dc.type.docTypeArticle-
dc.identifier.kciidART002196430-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasssci-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaPhysics-
dc.relation.journalWebOfScienceCategoryPhysics, Multidisciplinary-
dc.subject.keywordPlusINTENSITY-MODULATED RADIOTHERAPY-
dc.subject.keywordPlusSETUP UNCERTAINTIES-
dc.subject.keywordPlusIMMOBILIZATION SYSTEMS-
dc.subject.keywordPlusPATIENT IMMOBILIZATION-
dc.subject.keywordPlusRADIATION-THERAPY-
dc.subject.keywordPlusHEAD-
dc.subject.keywordPlusCARCINOMA-
dc.subject.keywordPlusACCURACY-
dc.subject.keywordPlusMARGIN-
dc.subject.keywordPlusLARYNX-
dc.subject.keywordAuthorPatient setup errors-
dc.subject.keywordAuthorThermoplastic mask-
dc.subject.keywordAuthorGlottis-
dc.subject.keywordAuthorCorrelation-
dc.subject.keywordAuthorTomotherapy-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Radiation Oncology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Bae, Sun Hyun photo

Bae, Sun Hyun
College of Medicine (Department of Radiation Oncology)
Read more

Altmetrics

Total Views & Downloads

BROWSE