Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

대퇴 중심정맥관 삽입을 위한 표면해부학적 위치와 대퇴 동맥 정맥의 관계 확인: 초음파를 이용한 전향적 연구Confirmation of the Relation between Femoral Artery and Vein for Central Venous Cannulation: A Prospective Investigation Using Ultrasound

Other Titles
Confirmation of the Relation between Femoral Artery and Vein for Central Venous Cannulation: A Prospective Investigation Using Ultrasound
Authors
박연순김혜정이보라이경민신희준김호중김기운임훈조영순
Issue Date
2017
Publisher
대한응급의학회
Keywords
Catheterization; central venous; Femoral vein; Anatomic landmarks; Ultrasonography
Citation
대한응급의학회지, v.28, no.4, pp.345 - 353
Journal Title
대한응급의학회지
Volume
28
Number
4
Start Page
345
End Page
353
URI
https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/8153
ISSN
1226-4334
Abstract
Purpose: Femoral vein catheterization is often performed using a landmark technique, despite the recommended method of using ultrasound guidance. Although the landmark-based procedure is a well-known, widely adopted method to date, there are insufficient studies validating the effectiveness of this method. Hence, the purpose of this study was to confirm the relationship between femoral artery and vein using an ultrasound, as well as to validate the effectiveness of the femoral vein catheterization method using the landmark technique. Methods: This was a prospective, repeated measurement study. Using an ultrasound with a 10 MHz transducer, the femoral vein cross-sectional areas on the right side were saved at a distance of 1, 2, 3, and 4 cm from the inguinal ligament with supine and hip abduction-external rotation positions. The width of the femoral vessels, center-to-center distance between the femoral artery and vein(horizontal distance between the center of the femoral artery and vein) and width of exposed femoral vein (not posterior to femoral artery) were measured. Results: The width of the femoral vein, the center-to-center distance between the femoral artery and vein, as well as the width of the exposed femoral vein were significantly decreased as the distance from the inguinal ligament was increased, regardless of the posture change (p<0.001). However, at a distance of 1 cm from the inguinal ligament, only 5.4% of the femoral veins were exposed without disturbance of the femoral artery, and there were also a few cases in which the femoral veins were not exposed at all. Conclusion: It appears that an ultrasound-guided femoral vein catheterization is recommended over the conventional landmark technique.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Emergency Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Ho Jung photo

Kim, Ho Jung
College of Medicine (Department of Emergency Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE