Comparison of Open-Cell Stent and Closed-Cell Stent for Treatment of Central Vein Stenosis or Occlusion in Hemodialysis Patients
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kang, Chae Hoon | - |
dc.contributor.author | Yang, Seung Boo | - |
dc.contributor.author | Lee, Woong Hee | - |
dc.contributor.author | Ahn, Jae Hong | - |
dc.contributor.author | Goo, Dong Erk | - |
dc.contributor.author | Han, Nae Jin | - |
dc.contributor.author | Ohm, Joon Young | - |
dc.date.accessioned | 2021-08-11T16:46:12Z | - |
dc.date.available | 2021-08-11T16:46:12Z | - |
dc.date.issued | 2016-10 | - |
dc.identifier.issn | 1735-1065 | - |
dc.identifier.issn | 2008-2711 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/8703 | - |
dc.description.abstract | Background: Central vein stenosis or occlusion is acommoncomplication that can lead to significant morbidity and dysfunction of access in the hemodialysis patient. More lesions can develop over time, and preserving access becomes a challenge as life expectancy of the hemodialysis patient increases. Objectives: The goal was to compare long-term results and determine the outcomes of open-cell stent versus closed-cell stent for central vein stenosis or occlusion in hemodialysis patients. Patients and Methods: From 1997 to 2015, in 401 hemodialysis patients, stent placement for central vein stenosis or occlusion was performed if balloon angioplasty was unsatisfactory, due to elastic recoil or occurrence of restenosis within 3 months. Whenthrombus was present, primary stenting was performed. A total of 257 open-cell stents and 144 closed-cell stents were used. Angiographic findings including lesion site, central vein stenosis or occlusion, and presence of thrombosis and complication were evaluated. Primary patency rate and mean patency rate of the stent were compared between two stent groups by Kaplan-Meier survival analysis. Results: For the open-cell stent group, 159 patients were diagnosed as central vein stenosis and 98 were occlusion. For the closed-cell stent group, 78 were stenosis and 66 were occlusion. There were two complications for central migration and two for procedurerelated vein rupture. Open-cell stents and closed-cell stents had mean patency rates of 10.9 +/- 0.80 months and 8.5 +/- 10.87 months, respectively (P = 0.002). Conclusion: The open-cell stent is effective and its performance is higher than that obtained with the closed-cell stent for treating central vein stenosis or occlusion in hemodialysis patients. | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | Kowsar | - |
dc.title | Comparison of Open-Cell Stent and Closed-Cell Stent for Treatment of Central Vein Stenosis or Occlusion in Hemodialysis Patients | - |
dc.type | Article | - |
dc.publisher.location | 네델란드 | - |
dc.identifier.doi | 10.5812/iranjradiol.37994 | - |
dc.identifier.scopusid | 2-s2.0-84994126546 | - |
dc.identifier.wosid | 000395456300019 | - |
dc.identifier.bibliographicCitation | Iranian Journal of Radiology, v.13, no.4 | - |
dc.citation.title | Iranian Journal of Radiology | - |
dc.citation.volume | 13 | - |
dc.citation.number | 4 | - |
dc.type.docType | Article | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.subject.keywordPlus | CENTRAL VENOUS OBSTRUCTION | - |
dc.subject.keywordPlus | NITINOL STENTS | - |
dc.subject.keywordPlus | SMART STENT | - |
dc.subject.keywordPlus | FOLLOW-UP | - |
dc.subject.keywordPlus | PLACEMENT | - |
dc.subject.keywordPlus | ANGIOPLASTY | - |
dc.subject.keywordPlus | DESIGN | - |
dc.subject.keywordPlus | ACCESS | - |
dc.subject.keywordPlus | WALLSTENTS | - |
dc.subject.keywordPlus | EXPERIENCE | - |
dc.subject.keywordAuthor | Dialysis | - |
dc.subject.keywordAuthor | Veins | - |
dc.subject.keywordAuthor | Angioplasty | - |
dc.subject.keywordAuthor | Stents | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(31538) 22, Soonchunhyang-ro, Asan-si, Chungcheongnam-do, Republic of Korea+82-41-530-1114
COPYRIGHT 2021 by SOONCHUNHYANG UNIVERSITY ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.