Accuracy and precision of minimally-invasive cardiac output monitoring in children: a systematic review and meta-analysis
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Suehiro, Koichi | - |
dc.contributor.author | Joosten, Alexandre | - |
dc.contributor.author | Murphy, Linda Suk-Ling | - |
dc.contributor.author | Desebbe, Olivier | - |
dc.contributor.author | Alexander, Brenton | - |
dc.contributor.author | Kim, Sang-Hyun | - |
dc.contributor.author | Cannesson, Maxime | - |
dc.date.accessioned | 2021-08-11T16:46:25Z | - |
dc.date.available | 2021-08-11T16:46:25Z | - |
dc.date.issued | 2016-10 | - |
dc.identifier.issn | 1387-1307 | - |
dc.identifier.issn | 1573-2614 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/8728 | - |
dc.description.abstract | Several minimally-invasive technologies are available for cardiac output (CO) measurement in children, but the accuracy and precision of these devices have not yet been evaluated in a systematic review and meta-analysis. We conducted a comprehensive search of the medical literature in PubMed, Cochrane Library of Clinical Trials, Scopus, and Web of Science from its inception to June 2014 assessing the accuracy and precision of all minimally-invasive CO monitoring systems used in children when compared with CO monitoring reference methods. Pooled mean bias, standard deviation, and mean percentage error of included studies were calculated using a random-effects model. The inter-study heterogeneity was also assessed using an I-2 statistic. A total of 20 studies (624 patients) were included. The overall random-effects pooled bias, and mean percentage error were 0.13 +/- 0.44 l min(-1) and 29.1 %, respectively. Significant inter-study heterogeneity was detected (P < 0.0001, I-2 = 98.3 %). In the sub-analysis regarding the device, electrical cardiometry showed the smallest bias (-0.03 l min(-1)) and lowest percentage error (23.6 %). Significant residual heterogeneity remained after conducting sensitivity and subgroup analyses based on the various study characteristics. By meta-regression analysis, we found no independent effects of study characteristics on weighted mean difference between reference and tested methods. Although the pooled bias was small, the mean pooled percentage error was in the gray zone of clinical applicability. In the sub-group analysis, electrical cardiometry was the device that provided the most accurate measurement. However, a high heterogeneity between studies was found, likely due to a wide range of study characteristics. | - |
dc.format.extent | 18 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | Kluwer Academic Publishers | - |
dc.title | Accuracy and precision of minimally-invasive cardiac output monitoring in children: a systematic review and meta-analysis | - |
dc.type | Article | - |
dc.publisher.location | 독일 | - |
dc.identifier.doi | 10.1007/s10877-015-9757-9 | - |
dc.identifier.scopusid | 2-s2.0-84940094201 | - |
dc.identifier.wosid | 000383602300014 | - |
dc.identifier.bibliographicCitation | Journal of Clinical Monitoring and Computing, v.30, no.5, pp 603 - 620 | - |
dc.citation.title | Journal of Clinical Monitoring and Computing | - |
dc.citation.volume | 30 | - |
dc.citation.number | 5 | - |
dc.citation.startPage | 603 | - |
dc.citation.endPage | 620 | - |
dc.type.docType | Article | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Anesthesiology | - |
dc.relation.journalWebOfScienceCategory | Anesthesiology | - |
dc.subject.keywordPlus | RECORDING ANALYTICAL METHOD | - |
dc.subject.keywordPlus | FEMORAL-ARTERY THERMODILUTION | - |
dc.subject.keywordPlus | CONGENITAL HEART-DISEASE | - |
dc.subject.keywordPlus | WAVE-FORM ANALYSIS | - |
dc.subject.keywordPlus | DIRECT FICK | - |
dc.subject.keywordPlus | TRANSPULMONARY THERMODILUTION | - |
dc.subject.keywordPlus | ELECTRICAL VELOCIMETRY | - |
dc.subject.keywordPlus | ULTRASOUND DILUTION | - |
dc.subject.keywordPlus | TRANSTHORACIC ECHOCARDIOGRAPHY | - |
dc.subject.keywordPlus | DOPPLER DETERMINATION | - |
dc.subject.keywordAuthor | Cardiac output | - |
dc.subject.keywordAuthor | Children | - |
dc.subject.keywordAuthor | Hemodynamic monitoring | - |
dc.subject.keywordAuthor | Meta-analysis | - |
dc.subject.keywordAuthor | Accuracy | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(31538) 22, Soonchunhyang-ro, Asan-si, Chungcheongnam-do, Republic of Korea+82-41-530-1114
COPYRIGHT 2021 by SOONCHUNHYANG UNIVERSITY ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.