Soft Membrane Sheath for Endoscopic Surgery of Intracerebral Hematomas
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Hwang, Sun-Chul | - |
dc.contributor.author | Yeo, Dong-Gyu | - |
dc.contributor.author | Shin, Dong-Seong | - |
dc.contributor.author | Kim, Bum-Tae | - |
dc.date.accessioned | 2021-08-11T17:43:50Z | - |
dc.date.available | 2021-08-11T17:43:50Z | - |
dc.date.issued | 2016-06 | - |
dc.identifier.issn | 1878-8750 | - |
dc.identifier.issn | 1878-8769 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/9071 | - |
dc.description.abstract | BACKGROUND: Although the functional efficacy of surgical evacuation of an intracerebral hematoma (ICH) remains controversial, it has a valuable role for managing ICHs. Endoscopic surgery is increasingly used to evacuate ICHs; however, the narrow rigid sheath may be limiting. We report the usefulness of a soft plastic membrane sheath for endoscopic evacuation of ICHs. METHODS: The 20 x 100-mm flat membrane sheath was made of polyester film. Before introducing the sheath into the ICH cavity under navigation, one side was tucked into the opposite side to make a narrow four-layered tube. After inserting it in the brain, the tucked-in leaf was pulled out, and the slit-like tube was ready to remove the hematoma. A rigid endoscope and various instruments were introduced into the sheath. Large ICHs in the putamen and thalamus were evacuated under endoscopic visualization using the same microsurgical instruments. RESULTS: This technique was applied to 41 patients. Nearly complete evacuation of all hematomas was achieved. No surgical complication or rebleeding occurred. The new membrane sheath allowed more room for accommodating and handling the instruments, including bipolar forceps. CONCLUSIONS: This flat membrane sheath is disposable and easy to prepare, which could overcome the limitation of the instruments to allow for efficient evacuation of an ICH using the same microsurgical techniques. | - |
dc.format.extent | 5 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | Elsevier BV | - |
dc.title | Soft Membrane Sheath for Endoscopic Surgery of Intracerebral Hematomas | - |
dc.type | Article | - |
dc.publisher.location | 미국 | - |
dc.identifier.doi | 10.1016/j.wneu.2016.03.001 | - |
dc.identifier.scopusid | 2-s2.0-84962194618 | - |
dc.identifier.wosid | 000380360500034 | - |
dc.identifier.bibliographicCitation | World Neurosurgery, v.90, pp 268 - 272 | - |
dc.citation.title | World Neurosurgery | - |
dc.citation.volume | 90 | - |
dc.citation.startPage | 268 | - |
dc.citation.endPage | 272 | - |
dc.type.docType | Article | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | sci | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Neurosciences & Neurology | - |
dc.relation.journalResearchArea | Surgery | - |
dc.relation.journalWebOfScienceCategory | Clinical Neurology | - |
dc.relation.journalWebOfScienceCategory | Surgery | - |
dc.subject.keywordPlus | HEMORRHAGE | - |
dc.subject.keywordPlus | EVACUATION | - |
dc.subject.keywordPlus | REMOVAL | - |
dc.subject.keywordAuthor | Endoscopic surgery | - |
dc.subject.keywordAuthor | Hematoma evacuation | - |
dc.subject.keywordAuthor | Intracerebral hematoma | - |
dc.subject.keywordAuthor | Membrane sheath | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(31538) 22, Soonchunhyang-ro, Asan-si, Chungcheongnam-do, Republic of Korea+82-41-530-1114
COPYRIGHT 2021 by SOONCHUNHYANG UNIVERSITY ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.