Detailed Information

Cited 0 time in webofscience Cited 5 time in scopus
Metadata Downloads

Comparison of Iohexol-380 and Iohexol-350 for Coronary CT Angiography: A Multicenter, Randomized, Double-Blind Phase 3 Trial

Full metadata record
DC Field Value Language
dc.contributor.authorPark, Eun-Ah-
dc.contributor.authorLee, Whal-
dc.contributor.authorKang, Doo Kyoung-
dc.contributor.authorKim, Sung Jin-
dc.contributor.authorKim, Young-Ju-
dc.contributor.authorKim, Yookyung-
dc.contributor.authorSung, Yon Mi-
dc.contributor.authorSong, Soon-Young-
dc.contributor.authorOh, Yu-Whan-
dc.contributor.authorYong, Hwan Seok-
dc.contributor.authorLee, Heon-
dc.contributor.authorJeon, Eui-Yong-
dc.contributor.authorJin, Gong-Yong-
dc.contributor.authorChoi, Byoung Wook-
dc.contributor.authorChoi, Sang-Il-
dc.date.accessioned2021-08-11T17:44:46Z-
dc.date.available2021-08-11T17:44:46Z-
dc.date.issued2016-05-
dc.identifier.issn1229-6929-
dc.identifier.issn2005-8330-
dc.identifier.urihttps://scholarworks.bwise.kr/sch/handle/2021.sw.sch/9174-
dc.description.abstractObjective: This multi-center, randomized, double-blind, phase 3 trial was conducted to compare the safety and efficacy of contrast agents iohexol-380 and iohexol-350 for coronary CT angiography in healthy subjects. Materials and Methods: Volunteers were randomized to receive 420 mgI/kg of either iohexol-350 or iohexol-380 using a flow rate of 4 mL/sec. All adverse events were recorded. Two blinded readers independently reviewed the CT images and conflicting results were resolved by a third reader. Luminal attenuations (ascending aorta, Left main coronary artery, and Left ventricle) in Hounsfield units (HUs) and image quality on a 4-point scale were calculated. Results: A total of 225 subjects were given contrast media (115 with iohexol-380 and 110 with iohexoL-350). There was no difference in number of adverse drug reactions between groups: 75 events in 56 (48.7%) of 115 subjects in the iohexol-380 group vs. 74 events in 51 (46.4%) of 110 subjects in the iohexol-350 group (p = 0.690). No severe adverse drug reactions were recorded. Neither group showed an increase in serum creatinine. Significant differences in mean density between the groups was found in the ascending aorta: 375.8 71.4 HU with iohexol-380 vs. 356.3 61.5 HU with iohexoL-350 (p = 0.030). No significant differences in image quality scores between both groups were observed for all three anatomic evaluations (all, p > 0.05). Conclusion: Iohexol-380 provides improved enhancement of the ascending aorta and similar attenuation of the coronary arteries without any increase in adverse drug reactions, as compared with iohexol-350 using an identical amount of total iodine.-
dc.format.extent9-
dc.language영어-
dc.language.isoENG-
dc.publisher대한영상의학회-
dc.titleComparison of Iohexol-380 and Iohexol-350 for Coronary CT Angiography: A Multicenter, Randomized, Double-Blind Phase 3 Trial-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.doi10.3348/kjr.2016.17.3.330-
dc.identifier.scopusid2-s2.0-84964265526-
dc.identifier.wosid000375889600003-
dc.identifier.bibliographicCitationKorean Journal of Radiology, v.17, no.3, pp 330 - 338-
dc.citation.titleKorean Journal of Radiology-
dc.citation.volume17-
dc.citation.number3-
dc.citation.startPage330-
dc.citation.endPage338-
dc.type.docTypeArticle-
dc.identifier.kciidART002112432-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.subject.keywordPlusCONCENTRATION CONTRAST-MEDIA-
dc.subject.keywordPlusCOMPUTED-TOMOGRAPHY-
dc.subject.keywordPlusIODINE-CONCENTRATION-
dc.subject.keywordPlusIMAGE QUALITY-
dc.subject.keywordPlusIOMEPROL 400-
dc.subject.keywordPlusCARDIAC CT-
dc.subject.keywordPlusENHANCEMENT-
dc.subject.keywordPlusPRINCIPLES-
dc.subject.keywordPlusATTENUATION-
dc.subject.keywordPlusRATIONALE-
dc.subject.keywordAuthorCoronary arteries-
dc.subject.keywordAuthorContrast media-
dc.subject.keywordAuthorContrast materials-
dc.subject.keywordAuthorDrug safety-
dc.subject.keywordAuthorImage quality enhancement-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Radiology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE