Transvenous Lead Extraction via the Inferior Approach Using a Gooseneck Snare versus Simple Manual Traction
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Jo, Uk | - |
dc.contributor.author | Kim, Jun | - |
dc.contributor.author | Hwang, You-Mi | - |
dc.contributor.author | Lee, Ji-Hyun | - |
dc.contributor.author | Kim, Min-Su | - |
dc.contributor.author | Choi, Hyung-Oh | - |
dc.contributor.author | Lee, Woo-Seok | - |
dc.contributor.author | Kwon, Chang-Hee | - |
dc.contributor.author | Ko, Gi-Young | - |
dc.contributor.author | Yoon, Hyun-Ki | - |
dc.contributor.author | Nam, Gi-Byoung | - |
dc.contributor.author | Choi, Kee-Joon | - |
dc.contributor.author | Kim, You-Ho | - |
dc.date.accessioned | 2021-08-11T17:46:06Z | - |
dc.date.available | 2021-08-11T17:46:06Z | - |
dc.date.issued | 2016-03 | - |
dc.identifier.issn | 1738-5520 | - |
dc.identifier.issn | 1738-5555 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/9309 | - |
dc.description.abstract | Background and Objectives: The number of patients with cardiac implantable electronic devices needing lead extraction is increasing for various reasons, including infections, vascular obstruction, and lead failure. We report our experience with transvenous extraction of pacemaker and defibrillator leads via the inferior approach of using a gooseneck snare as a first-line therapy and compare extraction using a gooseneck snare with extraction using simple manual traction. Subjects and Methods: The study included 23 consecutive patients (43 leads) who underwent transvenous lead extraction using a gooseneck snare (group A) and 10 consecutive patients (17 leads) who underwent lead extraction using simple manual traction (group B). Patient characteristics, indications, and outcomes were analyzed and compared between the groups. Results: The dwelling time of the leads was longer in group A (median, 121) than in group B (median, 56; p=0.000). No differences were noted in the overall procedural success rate (69.6% vs. 70%), clinical procedural success rate (82.6% vs. 90%), and lead clinical success rate (86% vs: 94.1%) between the groups. The procedural success rates according to lead type were 89.2% and 100% for pacing leads and 66.7% and 83.3% for defibrillator leads in groups A and B, respectively. Major complications were noted in 3 (mortality in 1) patients in group A and 2 patients in group B. Conclusion: Transvenous extraction of pacemaker leads via an inferior approach using a gooseneck snare was both safe and effective. However, stand-alone transvenous extraction of defibrillator leads using the inferior approach was suboptimal. | - |
dc.format.extent | 11 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | 대한심장학회 | - |
dc.title | Transvenous Lead Extraction via the Inferior Approach Using a Gooseneck Snare versus Simple Manual Traction | - |
dc.type | Article | - |
dc.publisher.location | 대한민국 | - |
dc.identifier.doi | 10.4070/kcj.2016.46.2.186 | - |
dc.identifier.scopusid | 2-s2.0-84962783546 | - |
dc.identifier.wosid | 000373032300009 | - |
dc.identifier.bibliographicCitation | Korean Circulation Journal, v.46, no.2, pp 186 - 196 | - |
dc.citation.title | Korean Circulation Journal | - |
dc.citation.volume | 46 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 186 | - |
dc.citation.endPage | 196 | - |
dc.type.docType | Article | - |
dc.identifier.kciid | ART002091007 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kci | - |
dc.relation.journalResearchArea | Cardiovascular System & Cardiology | - |
dc.relation.journalWebOfScienceCategory | Cardiac & Cardiovascular Systems | - |
dc.subject.keywordPlus | IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS | - |
dc.subject.keywordPlus | SINGLE-CENTER EXPERIENCE | - |
dc.subject.keywordPlus | DUAL-COIL | - |
dc.subject.keywordPlus | PACEMAKER | - |
dc.subject.keywordPlus | FAILURE | - |
dc.subject.keywordPlus | REMOVAL | - |
dc.subject.keywordPlus | PREDICTORS | - |
dc.subject.keywordPlus | STANDARD | - |
dc.subject.keywordPlus | SHEATHS | - |
dc.subject.keywordPlus | PATIENT | - |
dc.subject.keywordAuthor | Pacemaker, artificial | - |
dc.subject.keywordAuthor | Defibrillators, implantable | - |
dc.subject.keywordAuthor | Device removal | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(31538) 22, Soonchunhyang-ro, Asan-si, Chungcheongnam-do, Republic of Korea+82-41-530-1114
COPYRIGHT 2021 by SOONCHUNHYANG UNIVERSITY ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.