Comparison of Sesamoid Bone Position and Hallux Valgus Angle in Weight Bearing Conditions between Subjects with and without Hallux Valgus
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김문환 | - |
dc.contributor.author | 전인철 | - |
dc.contributor.author | 황의재 | - |
dc.contributor.author | 김영 | - |
dc.date.accessioned | 2021-08-11T18:25:42Z | - |
dc.date.available | 2021-08-11T18:25:42Z | - |
dc.date.issued | 2016 | - |
dc.identifier.issn | 1229-0475 | - |
dc.identifier.issn | 2287-156X | - |
dc.identifier.uri | https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/9572 | - |
dc.description.abstract | Purpose: Previous studies reported changes in the first metatarsophalangeal (MTP) joint angle in relation with and without weight bearing, but it is unclear whether sesamoid bone of the great toe changes in weight bearing conditions particularly in subjects with hallux valgus (HV). To investigate how weight bearing conditions can affect the position of the medial sesamoid bone (MSB), first MTP joint angle, and second intermetatarsal angle (IMA) in the recruited subjects. Methods: Subjects were recruited 24 with HV and 21 without HV in study. X-rays were taken in the weight bearing and non-weight bearing conditions. The distance of the MSB, first MTP joint angle, and second IMA were measured from the radiographs. Data were analyzed by paired and Independent t-test. The statistical significance level was p<0.05. Results: In both groups, the first MTP joint angles and the distance of the MSB were significantly smaller, while the second IMA was significantly greater in the weight bearing condition. The difference in the distance of the MSB between the two postures was significantly greater in the group with HV. Conclusion: Weight bearing can affect the first MTP joint angle, second IMA, and position of the MSB; the change in the position of the MSB in weight bearing was greater in the group with hallux valgus. The difference in these variables between weight bearing and non-weight bearing conditions may be considered when measuring HV. | - |
dc.format.extent | 4 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | 대한물리치료학회 | - |
dc.title | Comparison of Sesamoid Bone Position and Hallux Valgus Angle in Weight Bearing Conditions between Subjects with and without Hallux Valgus | - |
dc.title.alternative | Comparison of Sesamoid Bone Position and Hallux Valgus Angle in Weight Bearing Conditions between Subjects with and without Hallux Valgus | - |
dc.type | Article | - |
dc.publisher.location | 대한민국 | - |
dc.identifier.bibliographicCitation | 대한물리치료학회지, v.28, no.6, pp 381 - 384 | - |
dc.citation.title | 대한물리치료학회지 | - |
dc.citation.volume | 28 | - |
dc.citation.number | 6 | - |
dc.citation.startPage | 381 | - |
dc.citation.endPage | 384 | - |
dc.identifier.kciid | ART002192168 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | kci | - |
dc.subject.keywordAuthor | Hallux valgus | - |
dc.subject.keywordAuthor | Radiography | - |
dc.subject.keywordAuthor | Sesamoid bones | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(31538) 22, Soonchunhyang-ro, Asan-si, Chungcheongnam-do, Republic of Korea+82-41-530-1114
COPYRIGHT 2021 by SOONCHUNHYANG UNIVERSITY ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.