Comparison of Two Different Immobilization Devices for Pelvic Region Radiotherapy in TomotherapyComparison of Two Different Immobilization Devices for Pelvic Region Radiotherapy in Tomotherapy

Other Titles
Comparison of Two Different Immobilization Devices for Pelvic Region Radiotherapy in Tomotherapy
Authors
김대건James J Jung조광환류미령문성권배선현안재욱정재홍
Issue Date
2016
Publisher
한국의학물리학회
Keywords
Tomotherapy; Immobilization; Setup error; MVCT
Citation
PROGRESS in MEDICAL PHYSICS, v.27, no.4, pp 250 - 257
Pages
8
Journal Title
PROGRESS in MEDICAL PHYSICS
Volume
27
Number
4
Start Page
250
End Page
257
URI
https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/9573
DOI
10.14316/pmp.2016.27.4.250
ISSN
2508-4445
Abstract
The purpose of this study was to compare the patient setup errors of two different immobilization devices (Feet Fix: FF and Leg Fix: LF) for pelvic region radiotherapy in Tomotherapy. Thirty six-patients previously treated with IMRT technique were selected, and divided into two groups based on applied immobilization devices (FF versus LF). We performed a retrospective clinical analysis including the mean, systematic, random variation, 3D-error, and calculated the planning target volume (PTV) margin. In addition, a rotational error (angles, o) for each patient was analyzed using the automatic image registration. The 3D-errors for the FF and the LF groups were 3.70 mm and 4.26 mm, respectively; the LF group value was 15.1% higher than in the FF group. The treatment margin in the ML, SI, and AP directions were 5.23 mm (6.08 mm), 4.64 mm (6.29 mm), 5.83 mm (8.69 mm) in the FF group (and the LF group), respectively, that the FF group was lower than in the LF group. The percentage in treatment fractions for the FF group (ant the LF group) in greater than 5 mm at ML, SI, and AP direction was 1.7% (3.6%), 3.3% (10.7%), and 5.0% (16.1%), respectively. Two different immobilization devices were affected the patient setup errors due to different fixed location in low extremity. The radiotherapy for the pelvic region by Tomotherapy should be considering variation for the rotational angles including Yaw and Pitch direction that incorrect setup error during the treatment. In addition the choice of an appropriate immobilization device is important because an unalterable rotation angle affects the setup error.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Radiation Oncology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Bae, Sun Hyun photo

Bae, Sun Hyun
College of Medicine (Department of Radiation Oncology)
Read more

Altmetrics

Total Views & Downloads

BROWSE