Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

금 나노입자를 이용한 새로운 당화혈색소의 검출 기술

Full metadata record
DC Field Value Language
dc.contributor.author이수석-
dc.date.accessioned2021-08-11T18:25:56Z-
dc.date.available2021-08-11T18:25:56Z-
dc.date.created2021-06-17-
dc.date.issued2016-
dc.identifier.issn1225-5475-
dc.identifier.urihttps://scholarworks.bwise.kr/sch/handle/2021.sw.sch/9604-
dc.description.abstractWe report a novel detection technology for glycated hemoglobin (HbA1c) that is measured primarily to identify the three-month average plasma glucose concentration. In enzymatic measuring of glycated hemoglobin, the generated hydrogen peroxide was then used as a reducing agent of gold (III) for the synthesis of gold (0). Gold nanoparticles obtained from this novel approach were measured by optical and piezoelectric methods. In optical method, we have developed polymer based film-type sensor cartridge filled with all the reagents for glycated hemoglobin analysis and the cartridge worked very well having the detection limit of 0.53% of glycated hemoglobin. On the other hand, quartz crystal microbalance (QCM) sensors also have been developed to determine the abilities of surface modified QCM sensors at various levels of the concentration of glycated hemoglobin to bind gold nanoparticles and limit of detection was 0.90%. Finally, despite of relatively lower sensitivities of QCM sensor and film-type optical sensor than well-plate based optical detection, these two sensors were available to measure the glycated hemoglobin level for diabetes patients and normal person-
dc.language한국어-
dc.language.isoko-
dc.publisher한국센서학회-
dc.title금 나노입자를 이용한 새로운 당화혈색소의 검출 기술-
dc.title.alternativeNovel Detection Technology for Glycated Hemoglobin using Gold Nanoparticles-
dc.typeArticle-
dc.contributor.affiliatedAuthor이수석-
dc.identifier.doi1225-5475/eISSN2093-7563-
dc.identifier.bibliographicCitation센서학회지, v.25, no.6, pp.435 - 439-
dc.relation.isPartOf센서학회지-
dc.citation.title센서학회지-
dc.citation.volume25-
dc.citation.number6-
dc.citation.startPage435-
dc.citation.endPage439-
dc.type.rimsART-
dc.identifier.kciidART002170142-
dc.description.journalClass2-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorGlycated hemoglobin(HbA1c)-
dc.subject.keywordAuthorHydrogen peroxide-
dc.subject.keywordAuthorGold nanoparticle-
dc.subject.keywordAuthorFructosyl amino acid oxidase(FAOD)-
dc.subject.keywordAuthorFilm-type cartridge-
dc.subject.keywordAuthorQuartz Crystal Microbalance(QCM)-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medical Sciences > Department of Pharmaceutical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Soo Suk photo

Lee, Soo Suk
College of Medical Sciences (Department of Pharmaceutical Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE