dc.description.abstractThyroid nodules are common; however, malignancy is less than 7%. Therefore, additional techniques such as Doppler ultrasonography or elastography are used to improve diagnostic performance of conventional ultrasonography. We want to prospectively investigate the use of additional superb microvascular imaging (SMI) and strain elastography to B-mode ultrasound in thyroid nodules in distinguishing benign from malignant thyroid nodules. We analyzed 52 thyroid nodules (malignant = 26, benign = 26) and reviewers scored the likelihood of malignancy for three data sets (i.e., B-mode ultrasonography alone, B-mode ultrasonography + SMI, and B-mode ultrasonography + strain elastography). The area under the receiver-operating characteristic curve (Az) values, sensitivities, and specificities were compared. A comparison of the data sets revealed that area under the receiver-operating characteristic curve values were similar without statistical difference. However, on comparing sensitivity and specificity based on the management decision of whether to conduct fine-needle aspiration (FNA) after combining information from all three types of imaging (B-mode ultrasonography + SMI + strain elastography), specificity was significantly higher for the combined technique (34.6%) than for B-mode ultrasonography alone (11.5%), without decrease in sensitivity (P = 0.032). Additional use of SMI and strain elastography could potentially lead to increase in specificity in thyroid ultrasonography.-
dc.format.extent11-
dc.language영어-
dc.language.isoENG-
dc.publisherSPRINGER-VERLAG ITALIA SRL-
dc.titleDistinguishing benign from malignant thyroid nodules using thyroid ultrasonography: utility of adding superb microvascular imaging and elastography-
dc.typeArticle-
dc.identifier.doi10.1007/s11547-017-0839-2-
dc.identifier.bibliographicCitationRADIOLOGIA MEDICA, v.123, no.4, pp 260 - 270-
dc.description.isOpenAccessN-
dc.identifier.wosid000427504700003-
dc.identifier.scopusid2-s2.0-85038086247-
dc.citation.endPage270-
dc.citation.number4-
dc.citation.startPage260-
dc.citation.titleRADIOLOGIA MEDICA-
dc.citation.volume123-
dc.type.docTypeArticle-
dc.publisher.location이탈리아-
dc.subject.keywordAuthorElastography-
dc.subject.keywordAuthorSuperb microvascular imaging-
dc.subject.keywordAuthorThyroid nodule-
dc.subject.keywordAuthorUltrasonography-
dc.subject.keywordPlusFINE-NEEDLE-ASPIRATION-
dc.subject.keywordPlusCOLOR-DOPPLER-
dc.subject.keywordPlusCONSENSUS STATEMENT-
dc.subject.keywordPlusUS-ELASTOGRAPHY-
dc.subject.keywordPlusGRAY-SCALE-
dc.subject.keywordPlusULTRASOUND-
dc.subject.keywordPlusMANAGEMENT-
dc.subject.keywordPlusDIAGNOSIS-
dc.subject.keywordPlusFEATURES-
dc.subject.keywordPlusRECOMMENDATIONS-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > College of Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE