Cementless Bipolar Hemiarthroplasty Using a Micro-Arc Oxidation Coated Stem in Patients with Displaced Femoral Neck Fractures
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Young-Kyun | - |
dc.contributor.author | Joung, Ho-Yun | - |
dc.contributor.author | Kim, Sang-Hwan | - |
dc.contributor.author | Ha, Yong-Chan | - |
dc.contributor.author | Koo, Kyung-Hoi | - |
dc.date.available | 2019-03-08T20:41:21Z | - |
dc.date.issued | 2014-12 | - |
dc.identifier.issn | 0883-5403 | - |
dc.identifier.issn | 1532-8406 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/11522 | - |
dc.description.abstract | Femoral stem fixation for displaced femoral neck fractures in osteoporotic patients is an ongoing debate. We evaluated the outcome of 136 cementless bipolar hemiarthroplasty using a Micro-arc oxidation (MAO) coated stem. All patients survived the procedure and were discharged from the hospital. Thirty-and 90-day mortality rates were 0.7% and 2.2%, respectively. Ninety-eight hips were followed for a minimum of 2 years (mean, 44 months) postoperatively. Three stems were revised because of a periprosthetic fracture. Although cortical stress shielding around the stemwas observed in 3 hips, therewas no loosening or osteolysis. Cementless bipolar hemiarthroplasty using a MAO-coated stem is a useful and safe option to treat displaced femoral neck fractures. (C) 2014 Elsevier Inc. All rights reserved. | - |
dc.format.extent | 5 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | CHURCHILL LIVINGSTONE INC MEDICAL PUBLISHERS | - |
dc.title | Cementless Bipolar Hemiarthroplasty Using a Micro-Arc Oxidation Coated Stem in Patients with Displaced Femoral Neck Fractures | - |
dc.type | Article | - |
dc.identifier.doi | 10.1016/j.arth.2014.04.020 | - |
dc.identifier.bibliographicCitation | JOURNAL OF ARTHROPLASTY, v.29, no.12, pp 2388 - 2392 | - |
dc.description.isOpenAccess | N | - |
dc.identifier.wosid | 000345150900032 | - |
dc.identifier.scopusid | 2-s2.0-84912528560 | - |
dc.citation.endPage | 2392 | - |
dc.citation.number | 12 | - |
dc.citation.startPage | 2388 | - |
dc.citation.title | JOURNAL OF ARTHROPLASTY | - |
dc.citation.volume | 29 | - |
dc.type.docType | Article | - |
dc.publisher.location | 미국 | - |
dc.subject.keywordAuthor | femoral neck fracture | - |
dc.subject.keywordAuthor | cementless stem | - |
dc.subject.keywordAuthor | surface treatment | - |
dc.subject.keywordAuthor | micro-arc oxidation | - |
dc.subject.keywordAuthor | hemiarthroplasty | - |
dc.subject.keywordPlus | TOTAL HIP-ARTHROPLASTY | - |
dc.subject.keywordPlus | FOLLOW-UP | - |
dc.subject.keywordPlus | UNCEMENTED HEMIARTHROPLASTY | - |
dc.subject.keywordPlus | 30-DAY MORTALITY | - |
dc.subject.keywordPlus | LONG-STEM | - |
dc.subject.keywordPlus | REPLACEMENT | - |
dc.subject.keywordPlus | IMPLANTS | - |
dc.subject.keywordPlus | HYDROXYAPATITE | - |
dc.subject.keywordPlus | COMPONENT | - |
dc.subject.keywordPlus | BONE | - |
dc.relation.journalResearchArea | Orthopedics | - |
dc.relation.journalWebOfScienceCategory | Orthopedics | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
84, Heukseok-ro, Dongjak-gu, Seoul, Republic of Korea (06974)02-820-6194
COPYRIGHT 2019 Chung-Ang University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.