Detailed Information

Cited 8 time in webofscience Cited 7 time in scopus
Metadata Downloads

The correlation between retinal sensitivity assessed by microperimetry and contrast sensitivity in diabetic macular oedema

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Young Ho-
dc.contributor.authorYun, Cheolmin-
dc.contributor.authorKim, Jee Taek-
dc.contributor.authorKim, Seong-Woo-
dc.contributor.authorOh, Jaeryung-
dc.contributor.authorHuh, Kuhl-
dc.date.available2019-03-08T20:41:24Z-
dc.date.issued2014-12-
dc.identifier.issn0007-1161-
dc.identifier.issn1468-2079-
dc.identifier.urihttps://scholarworks.bwise.kr/cau/handle/2019.sw.cau/11525-
dc.description.abstractAim To investigate the relationship between contrast sensitivity (CS) and retinal sensitivity (RS) assessed by microperimetry (MP) in diabetic retinopathy (DR) with clinically significant macular oedema (CSME). Methods A retrospective study was performed with 35 eyes of 35 patients with DR and CSME. Retinal thickness (RT) and MP were tested with the spectral SD-optical coherence topography/scanning laser ophthalmoscope system. Mean central RT at the fovea centre's 1 mm zone (CRT) and at the fixation centre's 1 mm zone (FCRT) was measured. RS was tested at the fixation centre, within 2 degrees and 4 degrees areas. CS was measured with six target sizes (6.3 degrees, 4.0 degrees, 2.5 degrees, 1.6 degrees, 1.0 degrees, 0.64 degrees) with a contrast glare tester. Results The mean CRT and FCRT were 344.3 +/- 136.2 and 359.9 +/- 135.5 mu m, respectively. Mean log CSs (-log10) with the six target sizes ranged from 0.19 to 1.32. The mean RS at the fixation centre, within 2 degrees, and within 4 degrees area were 8.51 +/- 4.81 dB, 8.58 +/- 3.88 dB and 9.22 +/- 3.56 dB, respectively. RS at all tested areas were significantly correlated to log CS with all target sizes (range, r=0.366-0.755; =0.0001-0.030). CRT and FCRT were not significantly correlated to log CS or RS. Conclusions CS and RS showed moderately significant correlations in CSME. However, neither CS nor RS was correlated with RT in patients with CSME. It could be that CS and MP are complementary to each other and are useful tools in the evaluation of functional vision.-
dc.format.extent7-
dc.language영어-
dc.language.isoENG-
dc.publisherBMJ PUBLISHING GROUP-
dc.titleThe correlation between retinal sensitivity assessed by microperimetry and contrast sensitivity in diabetic macular oedema-
dc.typeArticle-
dc.identifier.doi10.1136/bjophthalmol-2013-304765-
dc.identifier.bibliographicCitationBRITISH JOURNAL OF OPHTHALMOLOGY, v.98, no.12, pp 1618 - 1624-
dc.description.isOpenAccessN-
dc.identifier.wosid000345284300004-
dc.identifier.scopusid2-s2.0-84919577496-
dc.citation.endPage1624-
dc.citation.number12-
dc.citation.startPage1618-
dc.citation.titleBRITISH JOURNAL OF OPHTHALMOLOGY-
dc.citation.volume98-
dc.type.docTypeArticle-
dc.publisher.location영국-
dc.subject.keywordPlusOPTICAL COHERENCE TOMOGRAPHY-
dc.subject.keywordPlusVISUAL-ACUITY-
dc.subject.keywordPlusTHICKNESS-
dc.subject.keywordPlusRETINOPATHY-
dc.subject.keywordPlusPERIMETRY-
dc.subject.keywordPlusINTEGRITY-
dc.subject.keywordPlusDISEASE-
dc.subject.keywordPlusEYES-
dc.relation.journalResearchAreaOphthalmology-
dc.relation.journalWebOfScienceCategoryOphthalmology-
dc.description.journalRegisteredClasssci-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > College of Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Jee Taek photo

Kim, Jee Taek
의과대학 (의학부(임상-서울))
Read more

Altmetrics

Total Views & Downloads

BROWSE