A facile and sensitive method for detecting pathogenic bacteria using personal glucose meters
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Joo, Jinmyoung | - |
dc.contributor.author | Kwon, Donghoon | - |
dc.contributor.author | Shin, Hwa Hui | - |
dc.contributor.author | Park, Ki-Hwan | - |
dc.contributor.author | Cha, Hyung Joon | - |
dc.contributor.author | Jeon, Sangmin | - |
dc.date.available | 2019-03-09T01:00:33Z | - |
dc.date.issued | 2013-11 | - |
dc.identifier.issn | 0925-4005 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/14169 | - |
dc.description.abstract | We report a facile and sensitive method for the detection of Salmonella bacteria in milk using a personal glucose meter (PGM). Monoclonal antibody-functionalized magnetic nanoparticle clusters (MNCs) were used to capture Salmonella bacteria in milk, and MNC-Salmonella complexes were magnetically separated from the sample using a permanent magnet. The complexes were further conjugated to polyclonal antibody-functionalized invertase and dispersed in a 0.5 M sucrose solution. After the hydrolysis of sucrose to glucose and fructose, the concentration of glucose was measured using the PGM. The hydrolysis reaction was conducted at various temperatures, and the optimal temperature and activation energy were determined. The detection limit of Salmonella in milk was found to be 10 cfu/mL. (C) 2013 Elsevier B. V. All rights reserved. | - |
dc.format.extent | 5 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | ELSEVIER SCIENCE SA | - |
dc.title | A facile and sensitive method for detecting pathogenic bacteria using personal glucose meters | - |
dc.type | Article | - |
dc.identifier.doi | 10.1016/j.snb.2013.08.027 | - |
dc.identifier.bibliographicCitation | SENSORS AND ACTUATORS B-CHEMICAL, v.188, pp 1250 - 1254 | - |
dc.description.isOpenAccess | N | - |
dc.identifier.wosid | 000326345600168 | - |
dc.identifier.scopusid | 2-s2.0-84883896820 | - |
dc.citation.endPage | 1254 | - |
dc.citation.startPage | 1250 | - |
dc.citation.title | SENSORS AND ACTUATORS B-CHEMICAL | - |
dc.citation.volume | 188 | - |
dc.type.docType | Article | - |
dc.publisher.location | 스위스 | - |
dc.subject.keywordAuthor | Salmonella | - |
dc.subject.keywordAuthor | Personal glucose meter | - |
dc.subject.keywordAuthor | Magnetic nanoparticle clusters | - |
dc.subject.keywordPlus | UNITED-STATES | - |
dc.subject.keywordPlus | IMMUNOMAGNETIC SEPARATION | - |
dc.subject.keywordPlus | ILLNESS | - |
dc.relation.journalResearchArea | Chemistry | - |
dc.relation.journalResearchArea | Electrochemistry | - |
dc.relation.journalResearchArea | Instruments & Instrumentation | - |
dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
dc.relation.journalWebOfScienceCategory | Electrochemistry | - |
dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
dc.description.journalRegisteredClass | sci | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
84, Heukseok-ro, Dongjak-gu, Seoul, Republic of Korea (06974)02-820-6194
COPYRIGHT 2019 Chung-Ang University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.