Supplementary Control of Conventional Coordinated Control for 1000 MW Ultra-supercritical Thermal Power Plant using Dynamic Matrix Control
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Youngjun | - |
dc.contributor.author | Yoo, Euiyeon | - |
dc.contributor.author | Lee, Taehyun | - |
dc.contributor.author | Moon, Un-Chul | - |
dc.date.available | 2019-01-22T14:16:17Z | - |
dc.date.issued | 2018-01 | - |
dc.identifier.issn | 1975-0102 | - |
dc.identifier.issn | 2093-7423 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/1423 | - |
dc.description.abstract | This paper proposes supplementary control of conventional coordinated control of a power plant which directly affects network frequency. The supplementary control with dynamic matrix control is applied for 1000 MW power plant with ultra-supercritical (USC) once-through boiler. The supplementary control signal is added to the boiler feedforward signal in the existing coordinated control logic. Therefore, it is a very practical structure that can maintain the existing multi-loop control system. This supplementary controller uses the step response model for the power plant system, and on-line optimization is performed at every sampling step. The simulation results demonstrate the effectiveness of the proposed supplementary control in a wide operating range of a practical 1000 MW USC power plant simulator. These results can contribute the stable operation of power system frequency. | - |
dc.format.extent | 8 | - |
dc.publisher | KOREAN INST ELECTR ENG | - |
dc.title | Supplementary Control of Conventional Coordinated Control for 1000 MW Ultra-supercritical Thermal Power Plant using Dynamic Matrix Control | - |
dc.type | Article | - |
dc.identifier.doi | 10.5370/JEET.2018.13.1.097 | - |
dc.identifier.bibliographicCitation | JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, v.13, no.1, pp 97 - 104 | - |
dc.identifier.kciid | ART002303669 | - |
dc.description.isOpenAccess | N | - |
dc.identifier.wosid | 000428478000011 | - |
dc.identifier.scopusid | 2-s2.0-85038822396 | - |
dc.citation.endPage | 104 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 97 | - |
dc.citation.title | JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY | - |
dc.citation.volume | 13 | - |
dc.type.docType | Article | - |
dc.publisher.location | 대한민국 | - |
dc.subject.keywordAuthor | Dynamic matrix control | - |
dc.subject.keywordAuthor | Coordinated control | - |
dc.subject.keywordAuthor | Boiler-turbine system | - |
dc.subject.keywordAuthor | Ultra-supercritical boiler (USC) power plant | - |
dc.subject.keywordPlus | ONCE-THROUGH BOILER | - |
dc.subject.keywordPlus | STEP-RESPONSE MODEL | - |
dc.subject.keywordPlus | TURBINE SYSTEM | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kci | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
84, Heukseok-ro, Dongjak-gu, Seoul, Republic of Korea (06974)02-820-6194
COPYRIGHT 2019 Chung-Ang University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.