Design Optimization of Structural Parameters for Highly Sensitive Photonic Crystal Label-Free Biosensors
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Ju, Jonghyun | - |
dc.contributor.author | Han, Yun-ah | - |
dc.contributor.author | Kim, Seok-min | - |
dc.date.available | 2019-03-09T02:02:21Z | - |
dc.date.issued | 2013-03 | - |
dc.identifier.issn | 1424-8220 | - |
dc.identifier.issn | 1424-3210 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/14814 | - |
dc.description.abstract | The effects of structural design parameters on the performance of nano-replicated photonic crystal (PC) label-free biosensors were examined by the analysis of simulated reflection spectra of PC structures. The grating pitch, duty, scaled grating height and scaled TiO2 layer thickness were selected as the design factors to optimize the PC structure. The peak wavelength value (PWV), full width at half maximum of the peak, figure of merit for the bulk and surface sensitivities, and surface/bulk sensitivity ratio were also selected as the responses to optimize the PC label-free biosensor performance. A parametric study showed that the grating pitch was the dominant factor for PWV, and that it had low interaction effects with other scaled design factors. Therefore, we can isolate the effect of grating pitch using scaled design factors. For the design of PC-label free biosensor, one should consider that: (1) the PWV can be measured by the reflection peak measurement instruments, (2) the grating pitch and duty can be manufactured using conventional lithography systems, and (3) the optimum design is less sensitive to the grating height and TiO2 layer thickness variations in the fabrication process. In this paper, we suggested a design guide for highly sensitive PC biosensor in which one select the grating pitch and duty based on the limitations of the lithography and measurement system, and conduct a multi objective optimization of the grating height and TiO2 layer thickness for maximizing performance and minimizing the influence of parameter variation. Through multi-objective optimization of a PC structure with a fixed grating height of 550 nm and a duty of 50%, we obtained a surface FOM of 66.18 RIU-1 and an S/B ratio of 34.8%, with a grating height of 117 nm and TiO2 height of 210 nm. | - |
dc.format.extent | 10 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | MDPI AG | - |
dc.title | Design Optimization of Structural Parameters for Highly Sensitive Photonic Crystal Label-Free Biosensors | - |
dc.type | Article | - |
dc.identifier.doi | 10.3390/s130303232 | - |
dc.identifier.bibliographicCitation | SENSORS, v.13, no.3, pp 3232 - 3241 | - |
dc.description.isOpenAccess | N | - |
dc.identifier.wosid | 000316612900035 | - |
dc.identifier.scopusid | 2-s2.0-84875155417 | - |
dc.citation.endPage | 3241 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 3232 | - |
dc.citation.title | SENSORS | - |
dc.citation.volume | 13 | - |
dc.type.docType | Article | - |
dc.publisher.location | 스위스 | - |
dc.subject.keywordAuthor | photonic crystal | - |
dc.subject.keywordAuthor | guided mode resonance | - |
dc.subject.keywordAuthor | biosensor | - |
dc.subject.keywordAuthor | design optimization | - |
dc.subject.keywordAuthor | desirability function | - |
dc.relation.journalResearchArea | Chemistry | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Instruments & Instrumentation | - |
dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
84, Heukseok-ro, Dongjak-gu, Seoul, Republic of Korea (06974)02-820-6194
COPYRIGHT 2019 Chung-Ang University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.