Reconfigurable RF receiver using compact distributed switch matrix for array coils
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, H. L. | - |
dc.date.available | 2019-05-28T01:37:45Z | - |
dc.date.issued | 2019-02 | - |
dc.identifier.issn | 0013-5194 | - |
dc.identifier.issn | 1350-911X | - |
dc.identifier.uri | https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/18236 | - |
dc.description.abstract | Magnetic resonance (MR) signals captured by RF array coils should be delivered to analogue-to-digital converter (ADC) channels through an independent receiver (Rx) circuitry for precise MRI process. Since different types of RF coils should be utilised by a fixed port configuration on a patient table with a limited number of ADC channels, a highly flexible Rx front-end design is necessary. In this Letter, a compact distributed switch matrix structure for multi-channel RF coil Rx is proposed for supporting different types of array coils with small circuit size and sufficient reconfigurability. The proposed structure is configured by a multiple number of unit matrix cells consisting of a single double pole double throw and two single pole double throw RF switches to control the pathways of received MR signals. The proposed structure was implemented and verified at 9.4-Tesla (9.4 T) MR frequency (400 MHz) by comparing different RF path losses. | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | INST ENGINEERING TECHNOLOGY-IET | - |
dc.title | Reconfigurable RF receiver using compact distributed switch matrix for array coils | - |
dc.type | Article | - |
dc.identifier.doi | 10.1049/el.2018.6579 | - |
dc.identifier.bibliographicCitation | ELECTRONICS LETTERS, v.55, no.3, pp 137 - + | - |
dc.description.isOpenAccess | N | - |
dc.identifier.wosid | 000457732200011 | - |
dc.identifier.scopusid | 2-s2.0-85061134132 | - |
dc.citation.endPage | + | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 137 | - |
dc.citation.title | ELECTRONICS LETTERS | - |
dc.citation.volume | 55 | - |
dc.type.docType | Article | - |
dc.publisher.location | 영국 | - |
dc.subject.keywordPlus | MRI | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
dc.description.journalRegisteredClass | sci | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
84, Heukseok-ro, Dongjak-gu, Seoul, Republic of Korea (06974)02-820-6194
COPYRIGHT 2019 Chung-Ang University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.