Usefulness of Virtual Expiratory CT Images to Compensate for Respiratory Liver Motion in Ultrasound/CT Image Fusion: A Prospective Study in Patients with Focal Hepatic Lesions
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kang, Tae Wook | - |
dc.contributor.author | Lee, Min Woo | - |
dc.contributor.author | Cha, Dong Ik | - |
dc.contributor.author | Park, Hyun Jung | - |
dc.contributor.author | Park, Jun Sung | - |
dc.contributor.author | Bang, Won-Chul | - |
dc.contributor.author | Kim, Seon Woo | - |
dc.date.available | 2019-05-28T01:38:43Z | - |
dc.date.issued | 2019-02 | - |
dc.identifier.issn | 1229-6929 | - |
dc.identifier.issn | 2005-8330 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/18264 | - |
dc.description.abstract | Objective: To assess whether virtual expiratory (VE)-computed tomography (CT)/ultrasound (US) fusion imaging is more effective than conventional inspiratory (CI)-CT/US fusion imaging for hepatic interventional procedures. Materials and Methods: This prospective study was approved by the Institutional Review Board, and informed consent was obtained from each patient. In total, 62 patients with focal hepatic lesions referred for hepatic interventional procedures were enrolled. VE-CT images were generated from CI-CT images to reduce the effects of respiration-induced liver motion. The two types of CT images were fused with real-time US images for each patient. The operators scored the visual similarity with the liver anatomy upon initial image fusion and the summative usability of complete image fusion using the respective five-point scales. The time required for complete image fusion and the number of point locks used were also compared. Results: In comparison with CI-CT/US fusion imaging, VE-CT/US fusion imaging showed significantly higher visual similarity with the liver anatomy on the initial image fusion (mean score, 3.9 vs. 1.7; p < 0.001) and higher summative usability for complete image fusion (mean score, 4.0 vs. 1.9; p < 0.001). The required time (mean, 11.1 seconds vs. 22.5 seconds; p < 0.001) and the number of point locks (mean, 1.6 vs. 3.0; p < 0.001) needed for complete image fusion using VE-CT/US fusion imaging were significantly tower than those needed for CI-CT/US fusion imaging. Conclusion: VE-CT/US fusion imaging is more effective than CI-CT/US fusion imaging for hepatic interventional procedures. | - |
dc.format.extent | 11 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | KOREAN RADIOLOGICAL SOC | - |
dc.title | Usefulness of Virtual Expiratory CT Images to Compensate for Respiratory Liver Motion in Ultrasound/CT Image Fusion: A Prospective Study in Patients with Focal Hepatic Lesions | - |
dc.type | Article | - |
dc.identifier.doi | 10.3348/kjr.2018.0320 | - |
dc.identifier.bibliographicCitation | KOREAN JOURNAL OF RADIOLOGY, v.20, no.2, pp 225 - 235 | - |
dc.identifier.kciid | ART002436562 | - |
dc.description.isOpenAccess | Y | - |
dc.identifier.wosid | 000456273800005 | - |
dc.identifier.scopusid | 2-s2.0-85060389781 | - |
dc.citation.endPage | 235 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 225 | - |
dc.citation.title | KOREAN JOURNAL OF RADIOLOGY | - |
dc.citation.volume | 20 | - |
dc.type.docType | Article | - |
dc.publisher.location | 대한민국 | - |
dc.subject.keywordAuthor | Ultrasonography | - |
dc.subject.keywordAuthor | Computed tomography | - |
dc.subject.keywordAuthor | Fusion imaging | - |
dc.subject.keywordAuthor | Liver | - |
dc.subject.keywordAuthor | Respiration | - |
dc.subject.keywordPlus | PERCUTANEOUS RADIOFREQUENCY ABLATION | - |
dc.subject.keywordPlus | COMPUTED-TOMOGRAPHY | - |
dc.subject.keywordPlus | MR-IMAGES | - |
dc.subject.keywordPlus | REGISTRATION | - |
dc.subject.keywordPlus | BIOPSY | - |
dc.subject.keywordPlus | TUMORS | - |
dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kci | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
84, Heukseok-ro, Dongjak-gu, Seoul, Republic of Korea (06974)02-820-6194
COPYRIGHT 2019 Chung-Ang University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.