Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Development of high performance liquid chromatography assay method of tramadol hydrochloride injection

Full metadata record
DC Field Value Language
dc.contributor.authorKim, DongHyeon-
dc.contributor.authorRhee, Hee Jae-
dc.contributor.authorMai, Xuan-Lan-
dc.contributor.authorKang, Jong-Seong-
dc.contributor.authorWoo, Mi Hee-
dc.contributor.authorNa, Dong-Hee-
dc.contributor.authorChun, In-Koo-
dc.contributor.authorKim, Kyeong Ho-
dc.date.available2019-03-07T04:40:32Z-
dc.date.issued2018-06-
dc.identifier.issn1225-0163-
dc.identifier.issn2288-8985-
dc.identifier.urihttps://scholarworks.bwise.kr/cau/handle/2019.sw.cau/2155-
dc.description.abstractCurrently, ultraviolet-visible spectrophotometry and titration methods are used for assay tests of tramadol hydrochloride injection and raw material in the Korean Pharmacopoeia XI (KP XI). Titration has also been used in the British Pharmacopoeia (BP 2013) for the assay test of tramadol hydrochloride, and the HPLC assay for tramadol hydrochloride raw material has been used in the United States Pharmacopeia (USP 39). In this study, we developed an alternative HPLC assay method for tramadol hydrochloride injection that is up to date and specific, and employs the same method as tramadol hydrochloride capsules. Validation of the HPLC method was conducted to determine linearity, precision, accuracy, system suitability, and robustness. The linearity of the calibration curves in the desired concentration range was good (r(2) > 0.9999). RSDs of intra-day precision obtained were 0.05-0.08% and inter-day precision obtained were 0.08-0.19%. Accuracy was obtained with recoveries in the range of 98.16% and 100.90%. As a result of the system's suitability, the RSD of both retention time and the peak area obtained were 0.07%. The values of the plate number and tailing factor of tramadol hydrochloride obtained were 7076 and 1.16, respectively. Because of the intermediate precision and robustness of the developed assay, it is expected to become a valuable tool for revising the Korean Pharmacopoeia (KP XI).-
dc.format.extent5-
dc.language영어-
dc.language.isoENG-
dc.publisherKOREAN SOC ANALYTICAL SCIENCE-
dc.titleDevelopment of high performance liquid chromatography assay method of tramadol hydrochloride injection-
dc.typeArticle-
dc.identifier.doi10.5806/AST.2018.31.3.107-
dc.identifier.bibliographicCitationANALYTICAL SCIENCE AND TECHNOLOGY, v.31, no.3, pp 107 - 111-
dc.identifier.kciidART002354957-
dc.description.isOpenAccessN-
dc.identifier.wosid000447066700001-
dc.citation.endPage111-
dc.citation.number3-
dc.citation.startPage107-
dc.citation.titleANALYTICAL SCIENCE AND TECHNOLOGY-
dc.citation.volume31-
dc.type.docTypeArticle-
dc.publisher.location대한민국-
dc.subject.keywordAuthorHPLC-
dc.subject.keywordAuthorKorean Pharmacopoeia (KP XI)-
dc.subject.keywordAuthorTramadol hydrochloride injection-
dc.subject.keywordAuthorAssay-
dc.subject.keywordAuthorValidation-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.description.journalRegisteredClassesci-
dc.description.journalRegisteredClasskci-
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Na, Dong Hee photo

Na, Dong Hee
대학원 (글로벌혁신신약학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE