Column-switching high-performance liquid chromatographic analysis of fluvastatin in rat plasma by direct injection

Full metadata record
DC Field Value Language
dc.contributor.authorUm, SY-
dc.contributor.authorJung, SH-
dc.contributor.authorJung, SJ-
dc.contributor.authorKim, JI-
dc.contributor.authorChung, SY-
dc.contributor.authorLee, HJ-
dc.contributor.authorHan, SB-
dc.contributor.authorChoi, SO-
dc.date.available2019-05-30T06:40:58Z-
dc.date.issued2006-06-
dc.identifier.issn0731-7085-
dc.identifier.issn1873-264X-
dc.identifier.urihttps://scholarworks.bwise.kr/cau/handle/2019.sw.cau/24325-
dc.description.abstractA column-switching high-performance liquid chromatographic (HPLC) method has been developed and validated for quantification of fluvastatin in rat plasma. Plasma samples were diluted with an equal volume of mobile phase, i.e. acetonitrile-5 mM potassium phosphate buffer (pH 6.8) (15:85, v/v), and the mixture was directly injected onto the HPLC system. The analyte was enriched in a pre-treatment column, while endogenous components were eluted to waste. The analyte was then back-flushed onto an analytical column and quantified with fluorescence detection (lambda(ex) = 305 nm; lambda(em) = 390 nm). The standard curve for the drug was linear in the range 0.5-100 ng mL(-1) in rat plasma. The limit of quantitation for plasma was found to be 0.5 ng mL(-1). This method has been fully validated and shown to be specific, accurate and precise. The method is simple and rapid because of a minimized sample preparation and appears to be useful for the pharmacokinetic study of fluvastatin. (c) 2006 Published by Elsevier B.V.-
dc.format.extent5-
dc.language영어-
dc.language.isoENG-
dc.publisherPERGAMON-ELSEVIER SCIENCE LTD-
dc.titleColumn-switching high-performance liquid chromatographic analysis of fluvastatin in rat plasma by direct injection-
dc.typeArticle-
dc.identifier.doi10.1016/j.jpba.2006.03.021-
dc.identifier.bibliographicCitationJOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, v.41, no.4, pp 1458 - 1462-
dc.description.isOpenAccessN-
dc.identifier.wosid000238491100059-
dc.identifier.scopusid2-s2.0-33646915183-
dc.citation.endPage1462-
dc.citation.number4-
dc.citation.startPage1458-
dc.citation.titleJOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS-
dc.citation.volume41-
dc.type.docTypeArticle-
dc.publisher.location네델란드-
dc.subject.keywordAuthorfluvastatin-
dc.subject.keywordAuthorcolumn-switching-
dc.subject.keywordAuthorhigh-performance liquid chromatography (HPLC)-
dc.subject.keywordAuthorrat plasma-
dc.subject.keywordAuthordirect injection-
dc.subject.keywordPlusCOA REDUCTASE INHIBITORS-
dc.subject.keywordPlusSAMPLE CLEANUP-
dc.subject.keywordPlusURINE-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalResearchAreaPharmacology & Pharmacy-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.relation.journalWebOfScienceCategoryPharmacology & Pharmacy-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Han, Sang Beom photo

Han, Sang Beom
약학대학 (약학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE