Detailed Information

Cited 6 time in webofscience Cited 7 time in scopus
Metadata Downloads

Polarization sensitivity and efficiency for a planar-type segmented germanium detector as a Compton polarimeter

Full metadata record
DC Field Value Language
dc.contributor.authorLee, JH-
dc.contributor.authorLee, CS-
dc.date.available2019-05-30T09:32:55Z-
dc.date.issued2003-06-
dc.identifier.issn0168-9002-
dc.identifier.issn1872-9576-
dc.identifier.urihttps://scholarworks.bwise.kr/cau/handle/2019.sw.cau/24977-
dc.description.abstractWe have investigated performance of a planar-type germanium detector with 25 segments as a Compton polarimeter to measure the linear polarization of gamma rays. We considered three different configurations in sampling horizontal and vertical Compton-scattering events for linearly polarized gamma rays incident on the detector. The experimental polarization sensitivity. Q, coincidence efficiency epsilon(coin), and figure of merit F for each configuration have been extracted for gamma rays of interest below 600 keV found in our previous in-beam spectroscopy on Gd-155. We also obtained theoretical values for these three quantities through a Monte Carlo simulation. Experimental values were in good accord with simulation results for all the three configurations. The third configuration, sampling pairs between the segment of incidence and any off-diagonal segments in coincidence, turned out to have the largest Q as well as epsilon(coin) value of all the three configurations, thereby resulting in the best figure of merit F. (C) 2003 Elsevier Science B.V. All rights reserved.-
dc.format.extent9-
dc.language영어-
dc.language.isoENG-
dc.publisherELSEVIER SCIENCE BV-
dc.titlePolarization sensitivity and efficiency for a planar-type segmented germanium detector as a Compton polarimeter-
dc.typeArticle-
dc.identifier.doi10.1016/S0168-9002(03)01369-X-
dc.identifier.bibliographicCitationNUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, v.506, no.1-2, pp 125 - 133-
dc.description.isOpenAccessN-
dc.identifier.wosid000183798000013-
dc.identifier.scopusid2-s2.0-0037701571-
dc.citation.endPage133-
dc.citation.number1-2-
dc.citation.startPage125-
dc.citation.titleNUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT-
dc.citation.volume506-
dc.type.docTypeArticle-
dc.publisher.location네델란드-
dc.subject.keywordAuthorplanar-type germanium detector-
dc.subject.keywordAuthor25 segments-
dc.subject.keywordAuthorCompton polarimeter-
dc.subject.keywordAuthorpolarization sensitivity-
dc.subject.keywordAuthorcoincidence efficiency-
dc.subject.keywordAuthorMonte Carlo simulation-
dc.subject.keywordPlusGAMMA-RAYS-
dc.subject.keywordPlusGD-155-
dc.relation.journalResearchAreaInstruments & Instrumentation-
dc.relation.journalResearchAreaNuclear Science & Technology-
dc.relation.journalResearchAreaPhysics-
dc.relation.journalWebOfScienceCategoryInstruments & Instrumentation-
dc.relation.journalWebOfScienceCategoryNuclear Science & Technology-
dc.relation.journalWebOfScienceCategoryPhysics, Nuclear-
dc.relation.journalWebOfScienceCategoryPhysics, Particles & Fields-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Natural Sciences > Department of Physics > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE