Detailed Information

Cited 10 time in webofscience Cited 10 time in scopus
Metadata Downloads

Advanced cleanup process of the free-flow microfluidic device for protein analysis

Full metadata record
DC Field Value Language
dc.contributor.authorHuh, Yun Suk-
dc.contributor.authorPark, Tae Jung-
dc.contributor.authorYang, KwangSuk-
dc.contributor.authorLee, Eun Zoo-
dc.contributor.authorHong, Yeon Ki-
dc.contributor.authorLee, Sang Yup-
dc.contributor.authorKim, Do Hyun-
dc.contributor.authorHong, Won Hi-
dc.date.available2019-07-09T04:55:47Z-
dc.date.issued2008-09-
dc.identifier.issn0304-3991-
dc.identifier.issn1879-2723-
dc.identifier.urihttps://scholarworks.bwise.kr/cau/handle/2019.sw.cau/27662-
dc.description.abstractThe treatment of samples preparation is generally recognized as a bottleneck for the rapid analysis of protein because of the off-chip performance in many cases. In this study, we used the charge characteristics of protein to develop a simple and rapid electro-microfluidic desalting system as an effective means of cleaning up protein sample. When we loaded a urea-rich protein sample and a buffer solution into a free-flow zone electrophoresis (FFZE) chamber, the microfluidic device was able to separate the charged protein sample and the non-charged urea. With a 90V electric field in the FFZE chamber, the removal efficiency of the urea was about 88% and the recovery of the protein was 78%. In addition, the desalted protein sample used in this device showed significant improvement with respect to the MALDI-TOF-MS spectrum signal of a fusion protein, which was fused to the gold-binding polypeptide with enhanced green fluorescent protein, as a model protein. The inflow of the purified fusion protein sample can be successfully immobilized on the gold surface and analyzed by confocal fluorescence microscopy and surface plasmon resonance for biotechnological sensors. (c) 2008 Elsevier B.V. All rights reserved.-
dc.format.extent6-
dc.language영어-
dc.language.isoENG-
dc.publisherELSEVIER SCIENCE BV-
dc.titleAdvanced cleanup process of the free-flow microfluidic device for protein analysis-
dc.typeArticle-
dc.identifier.doi10.1016/j.ultramic.2008.04.085-
dc.identifier.bibliographicCitationULTRAMICROSCOPY, v.108, no.10, pp 1365 - 1370-
dc.description.isOpenAccessN-
dc.identifier.wosid000259728000078-
dc.identifier.scopusid2-s2.0-50149107173-
dc.citation.endPage1370-
dc.citation.number10-
dc.citation.startPage1365-
dc.citation.titleULTRAMICROSCOPY-
dc.citation.volume108-
dc.type.docTypeArticle; Proceedings Paper-
dc.publisher.location네델란드-
dc.subject.keywordAuthorelectro-desalting-
dc.subject.keywordAuthormicrofluidic device-
dc.subject.keywordAuthorsample preparation-
dc.subject.keywordAuthorfusion protein-
dc.subject.keywordAuthorbiosensor-
dc.subject.keywordPlusSOLID-PHASE MICROEXTRACTION-
dc.subject.keywordPlusSAMPLE PREPARATION-
dc.subject.keywordPlusMASS-SPECTROMETRY-
dc.subject.keywordPlusMOLECULAR DIAGNOSTICS-
dc.subject.keywordPlusANALYSIS SYSTEMS-
dc.subject.keywordPlusSEPARATION-
dc.subject.keywordPlusELECTROPHORESIS-
dc.subject.keywordPlusCHIP-
dc.subject.keywordPlusCHROMATOGRAPHY-
dc.subject.keywordPlusEXTRACTION-
dc.relation.journalResearchAreaMicroscopy-
dc.relation.journalWebOfScienceCategoryMicroscopy-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Natural Sciences > Department of Chemistry > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Tae Jung photo

Park, Tae Jung
자연과학대학 (화학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE