Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

화재피해 감소 위한 자동소화장치 적용범위 개선

Full metadata record
DC Field Value Language
dc.contributor.author백창선-
dc.contributor.author박인선-
dc.date.available2019-03-08T06:38:03Z-
dc.date.issued2018-
dc.identifier.issn1738-3803-
dc.identifier.urihttps://scholarworks.bwise.kr/cau/handle/2019.sw.cau/3143-
dc.description.abstractThe rapid progress toward the 4th industrial society has led to possibilities of fire increase. It is pointed out that, though initial fire suppression is emphasized, the current legal systems do not sufficiently recognize the importance of initial fire suppression. In order to resolve this, problems of the current legal systems and regulations, as well as fire-fighting facilities to be equipped according to the size of specific fire-fighting objects, were diagnosed. Also, suggestions for improvement were provided through comparative analysis with relevant laws and technical regulations of Korea and other countries. According to fire safety standards such as NFPA, IMO, ISO, and Russian standards, automatic fire extinguishers are to be installed as per the adaptability criteria of fire extinguishers and automatic fire extinguishers. In Korea, the “Act on Fire Prevention and Installation, Maintenance, and Safety Control of Fire-fighting Systems“ cover the types and scope of fire fighting facilities that include specific fire protection objects, such as electric room, power room, and substation room. This study has identified that, in case of a place with a floor area of less than 300㎡, the installation requirement is not clearly specified. Therefore, in this study, fire extinguishing equipment and automatic fire extinguishing equipment to be added for each sub-use application are proved to have fire extinguishing performance of Class A, Class B, and Class C, respectively. In view of the fact that, in overseas standards, all space except containing such materials as Deep fire, metal fire and peroxide, can be installed with fire fighting equipment, a legal system for specifying the capacity units of fire fighting apparatus by application is, in this study, proposed.-
dc.description.abstractThe rapid progress toward the 4th industrial society has led to possibilities of fire increase. It is pointed out that, though initial fire suppression is emphasized, the current legal systems do not sufficiently recognize the importance of initial fire suppression. In order to resolve this, problems of the current legal systems and regulations, as well as fire-fighting facilities to be equipped according to the size of specific fire-fighting objects, were diagnosed. Also, suggestions for improvement were provided through comparative analysis with relevant laws and technical regulations of Korea and other countries. According to fire safety standards such as NFPA, IMO, ISO, and Russian standards, automatic fire extinguishers are to be installed as per the adaptability criteria of fire extinguishers and automatic fire extinguishers. In Korea, the “Act on Fire Prevention and Installation, Maintenance, and Safety Control of Fire-fighting Systems“ cover the types and scope of fire fighting facilities that include specific fire protection objects, such as electric room, power room, and substation room. This study has identified that, in case of a place with a floor area of less than 300㎡, the installation requirement is not clearly specified. Therefore, in this study, fire extinguishing equipment and automatic fire extinguishing equipment to be added for each sub-use application are proved to have fire extinguishing performance of Class A, Class B, and Class C, respectively. In view of the fact that, in overseas standards, all space except containing such materials as Deep fire, metal fire and peroxide, can be installed with fire fighting equipment, a legal system for specifying the capacity units of fire fighting apparatus by application is, in this study, proposed.-
dc.format.extent4-
dc.publisher한국안전학회-
dc.title화재피해 감소 위한 자동소화장치 적용범위 개선-
dc.title.alternativeImprovement to the Applicable Scope of Automatic Fire Extinguisher to Reduce Fire Damage-
dc.typeArticle-
dc.identifier.doi10.14346/JKOSOS.2018.33.1.62-
dc.identifier.bibliographicCitation한국안전학회지, v.33, no.1, pp 62 - 65-
dc.identifier.kciidART002322385-
dc.description.isOpenAccessN-
dc.citation.endPage65-
dc.citation.number1-
dc.citation.startPage62-
dc.citation.title한국안전학회지-
dc.citation.volume33-
dc.publisher.location대한민국-
dc.subject.keywordAuthorautomatic fire extinguisher-
dc.subject.keywordAuthorfire safety standards-
dc.subject.keywordAuthorthe types and scope of fire fighting facilities-
dc.description.journalRegisteredClasskci-
Files in This Item
There are no files associated with this item.
Appears in
Collections
Da Vinci College of General Education > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, In Seon photo

Park, In Seon
교양대학 (교양대학)
Read more

Altmetrics

Total Views & Downloads

BROWSE