dc.description.abstract | Flexible and wearable biosensors have great potential to interface with skin and noninvasively extract biofluids for real time and continuous monitoring of physiological status. Soft electronics is the prime factor in these wearables, regardless of sensing mechanism and fabrication technology. Wireless connectivity would be a valuable addition to enhance wearable biosensor's scope for remote and resource limited settings. These skin-adaptable, user-friendly, battery-free (although not all), and noninvasive devices continuously and simultaneously monitor wearer well-being and transfer data wirelessly. Thus, they have a great potential to improve quality of life with timely diagnostics and hence early treatments. However, they remain in the early stages, with relatively conventional sensing modalities, battery requirements, soft electronics fabrication limitations, and practicable size restrictions to retain skin compatibility. We classify wearable biosensors by sensing functionality, such as skin temperature, pH, heart rate, sweat glucose, uric acid, sweat electrolyte, cerebrospinal shunt flow, and toxic chemicals, and discuss challenges and prospects for these biosensors. © 2019 Elsevier B.V. | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | Elsevier Ltd | - |
dc.title | Recent advances in noninvasive flexible and wearable wireless biosensors | - |
dc.type | Article | - |
dc.identifier.doi | 10.1016/j.bios.2019.111422 | - |
dc.identifier.bibliographicCitation | Biosensors and Bioelectronics, v.141 | - |
dc.description.isOpenAccess | N | - |
dc.identifier.wosid | 000486132800007 | - |
dc.identifier.scopusid | 2-s2.0-85067518648 | - |
dc.citation.title | Biosensors and Bioelectronics | - |
dc.citation.volume | 141 | - |
dc.type.docType | Review | - |
dc.publisher.location | 영국 | - |
dc.subject.keywordAuthor | Biosensor | - |
dc.subject.keywordAuthor | Electrochemical | - |
dc.subject.keywordAuthor | Screen printing | - |
dc.subject.keywordAuthor | Stretchable | - |
dc.subject.keywordAuthor | Wearable | - |
dc.subject.keywordAuthor | Wireless | - |
dc.subject.keywordPlus | Biosensors | - |
dc.subject.keywordPlus | Electric batteries | - |
dc.subject.keywordPlus | Electrolytes | - |
dc.subject.keywordPlus | Radio | - |
dc.subject.keywordPlus | Screen printing | - |
dc.subject.keywordPlus | Continuous monitoring | - |
dc.subject.keywordPlus | Electrochemical | - |
dc.subject.keywordPlus | Fabrication Technologies | - |
dc.subject.keywordPlus | Physiological status | - |
dc.subject.keywordPlus | Stretchable | - |
dc.subject.keywordPlus | Wearable | - |
dc.subject.keywordPlus | Wireless biosensors | - |
dc.subject.keywordPlus | Wireless connectivities | - |
dc.subject.keywordPlus | Wearable technology | - |
dc.subject.keywordPlus | electrolyte | - |
dc.subject.keywordPlus | glucose | - |
dc.subject.keywordPlus | lactic acid | - |
dc.subject.keywordPlus | potassium | - |
dc.subject.keywordPlus | uric acid | - |
dc.subject.keywordPlus | controlled study | - |
dc.subject.keywordPlus | electrochemical analysis | - |
dc.subject.keywordPlus | heart rate | - |
dc.subject.keywordPlus | intraocular pressure | - |
dc.subject.keywordPlus | limit of detection | - |
dc.subject.keywordPlus | particle size | - |
dc.subject.keywordPlus | pH | - |
dc.subject.keywordPlus | Review | - |
dc.subject.keywordPlus | skin temperature | - |
dc.subject.keywordPlus | sweat | - |
dc.relation.journalResearchArea | Biophysics | - |
dc.relation.journalResearchArea | Biotechnology & Applied Microbiology | - |
dc.relation.journalResearchArea | Chemistry | - |
dc.relation.journalResearchArea | Electrochemistry | - |
dc.relation.journalResearchArea | Science & Technology - Other Topics | - |
dc.relation.journalWebOfScienceCategory | Biophysics | - |
dc.relation.journalWebOfScienceCategory | Biotechnology & Applied Microbiology | - |
dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
dc.relation.journalWebOfScienceCategory | Electrochemistry | - |
dc.relation.journalWebOfScienceCategory | Nanoscience & Nanotechnology | - |
dc.description.journalRegisteredClass | sci | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
84, Heukseok-ro, Dongjak-gu, Seoul, Republic of Korea (06974)02-820-6194
COPYRIGHT 2019 Chung-Ang University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.