Salvage Surgical Treatment for Failed Endovascular Procedure of a Blood Blister-Like Aneurysm
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Tack Geun Cho | - |
dc.contributor.author | 황성남 | - |
dc.contributor.author | 남택균 | - |
dc.contributor.author | 박승원 | - |
dc.date.available | 2019-08-23T02:02:12Z | - |
dc.date.issued | 2012 | - |
dc.identifier.issn | 2234-8565 | - |
dc.identifier.issn | 2287-3139 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/35527 | - |
dc.description.abstract | The blood blister-like aneurysm (BBA) of the internal carotid artery (ICA) is a rare but clinically important cause of subarachnoid hemorrhage (SAH), which accounts for 0.5% of incidences of ruptured intracranial aneurysms. BBA is a thin-walled, broad-based aneurysm that lacks an identifiable neck and is one of the most difficult lesions to treat. In this paper, a case is presented of a 57-year-old woman with SAH. Her cerebral angiography demonstrated a small BBA on the dorsal wall of her right ICA. Endovascular treatment that consisted of a stent-within-a-stent was attempted, but the replacement of the second stent failed, and the aneurysm became bigger. Surgery was performed by clipping the BBA with a Sundt slim-line encircling graft clip. The patient completely recovered with no complications. This treatment may be a salvageable option for BBA, especially when endovascular treatment has failed. | - |
dc.format.extent | 5 | - |
dc.publisher | 대한뇌혈관외과학회 | - |
dc.title | Salvage Surgical Treatment for Failed Endovascular Procedure of a Blood Blister-Like Aneurysm | - |
dc.type | Article | - |
dc.identifier.doi | 10.7461/jcen.2012.14.2.99 | - |
dc.identifier.bibliographicCitation | Journal of Cerebrovascular and Endovascular Neurosurgery, v.14, no.2, pp 99 - 103 | - |
dc.identifier.kciid | ART001674798 | - |
dc.description.isOpenAccess | N | - |
dc.citation.endPage | 103 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 99 | - |
dc.citation.title | Journal of Cerebrovascular and Endovascular Neurosurgery | - |
dc.citation.volume | 14 | - |
dc.publisher.location | 대한민국 | - |
dc.subject.keywordAuthor | Blood-blister like aneurysm | - |
dc.subject.keywordAuthor | Internal carotid artery | - |
dc.subject.keywordAuthor | Subarachnoid hemorrhage | - |
dc.subject.keywordAuthor | Encircling graft clip | - |
dc.subject.keywordAuthor | Endovascular stent | - |
dc.description.journalRegisteredClass | kciCandi | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
84, Heukseok-ro, Dongjak-gu, Seoul, Republic of Korea (06974)02-820-6194
COPYRIGHT 2019 Chung-Ang University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.