Integrated microsystems for the: In situ genetic detection of dengue virus in whole blood using direct sample preparation and isothermal amplification
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Yoo, Hyun Jin | - |
dc.contributor.author | Baek, Changyoon | - |
dc.contributor.author | Lee, Min-Ho | - |
dc.contributor.author | Min, Junhong | - |
dc.date.available | 2020-04-14T06:20:52Z | - |
dc.date.issued | 2020-03 | - |
dc.identifier.issn | 0003-2654 | - |
dc.identifier.issn | 1364-5528 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/38470 | - |
dc.description.abstract | Owing to the frequent outbreak of dengue fever worldwide, a highly sensitive but in situ simple process diagnostic device is required to detect the dengue virus. However, the current immune affinity-based methods have sensitivity issues and nucleic acid-based diagnostic devices have not been suitable for field diagnosis due to the complexity in sample preparation. Here, a simple and fast nucleic acid-based diagnostic tool to directly detect dengue viruses in whole blood is demonstrated using a microbead-assisted direct sample preparation buffer (MB-buffer) and isothermal amplification (loop-mediated isothermal amplification, LAMP). To maximize the performance of the sample preparation process in the microfluidic chip platform, the chemical composition of the sample preparation buffer is simplified and combined with physical tools (heating and bead beating). The entire serial processes consisted of only (1) sample (whole blood) loading, (2) stirring for 90 s, (3) heating at 70 °C for 10 min, and (4) LAMP amplification in the simply designed microfluidic chip cartridge. A single syringe was utilized for sample loading and microfluidic solution transfer. Consequently, dengue viruses were qualitatively detected and discriminated with high sensitivity (LOD: 102 PFU per 200 μL of whole blood) in less than 1 hour without the use of any sophisticated system. © 2020 The Royal Society of Chemistry. | - |
dc.format.extent | 7 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | Royal Society of Chemistry | - |
dc.title | Integrated microsystems for the: In situ genetic detection of dengue virus in whole blood using direct sample preparation and isothermal amplification | - |
dc.type | Article | - |
dc.identifier.doi | 10.1039/c9an02435b | - |
dc.identifier.bibliographicCitation | Analyst, v.145, no.6, pp 2405 - 2411 | - |
dc.description.isOpenAccess | N | - |
dc.identifier.wosid | 000528553800040 | - |
dc.identifier.scopusid | 2-s2.0-85081916902 | - |
dc.citation.endPage | 2411 | - |
dc.citation.number | 6 | - |
dc.citation.startPage | 2405 | - |
dc.citation.title | Analyst | - |
dc.citation.volume | 145 | - |
dc.type.docType | Article | - |
dc.publisher.location | 영국 | - |
dc.subject.keywordPlus | Fluidic devices | - |
dc.subject.keywordPlus | Isotherms | - |
dc.subject.keywordPlus | Microfluidics | - |
dc.subject.keywordPlus | Nucleic acids | - |
dc.subject.keywordPlus | Viruses | - |
dc.subject.keywordPlus | Chemical compositions | - |
dc.subject.keywordPlus | Diagnostic device | - |
dc.subject.keywordPlus | Integrated microsystems | - |
dc.subject.keywordPlus | Isothermal amplifications | - |
dc.subject.keywordPlus | Loop mediated isothermal amplifications | - |
dc.subject.keywordPlus | Process diagnostics | - |
dc.subject.keywordPlus | Sample preparation | - |
dc.subject.keywordPlus | Sophisticated system | - |
dc.subject.keywordPlus | Blood | - |
dc.relation.journalResearchArea | Chemistry | - |
dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
84, Heukseok-ro, Dongjak-gu, Seoul, Republic of Korea (06974)02-820-6194
COPYRIGHT 2019 Chung-Ang University All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.