A short-cut graphical method for sizing of recycle valves in anti-Surge system considering time delay

Full metadata record
DC Field Value Language
dc.contributor.authorOh, Yutaek-
dc.contributor.authorLee, Chul-Jin-
dc.contributor.authorLim, Youngsub-
dc.date.available2019-03-08T07:57:00Z-
dc.date.issued2017-10-
dc.identifier.issn0959-1524-
dc.identifier.issn1873-2771-
dc.identifier.urihttps://scholarworks.bwise.kr/cau/handle/2019.sw.cau/3903-
dc.description.abstractA surge in a centrifugal compressor can cause critical damage to the compressor, resulting in large repair costs, so one of the most important considerations in the design of compressor systems is to prevent a surge. However, conventional methods to size recycle valves in anti-surge systems are limited in that the valve characteristics and time delay cannot be quantitatively considered. This paper suggested a shortcut graphical method to easily size the recycle valves in an anti-surge system by considering the valve characteristics, including the dead time, actuation time, and opening types. Dynamic simulations were carried out to verify the resulting size of the valves, and the results of the simulation showed that a surge could be avoided effectively and economically. (C) 2017 Elsevier Ltd. All rights reserved.-
dc.format.extent10-
dc.language영어-
dc.language.isoENG-
dc.publisherELSEVIER SCI LTD-
dc.titleA short-cut graphical method for sizing of recycle valves in anti-Surge system considering time delay-
dc.typeArticle-
dc.identifier.doi10.1016/j.jprocont.2017.08.009-
dc.identifier.bibliographicCitationJOURNAL OF PROCESS CONTROL, v.58, pp 23 - 32-
dc.description.isOpenAccessN-
dc.identifier.wosid000419414600003-
dc.identifier.scopusid2-s2.0-85034099896-
dc.citation.endPage32-
dc.citation.startPage23-
dc.citation.titleJOURNAL OF PROCESS CONTROL-
dc.citation.volume58-
dc.type.docTypeArticle-
dc.publisher.location영국-
dc.subject.keywordAuthorProcess design-
dc.subject.keywordAuthorCompressor-
dc.subject.keywordAuthorSizing method-
dc.subject.keywordAuthorAnti-surge valves-
dc.subject.keywordAuthorDynamic simulation-
dc.subject.keywordPlusNONLINEAR-SYSTEMS-
dc.subject.keywordPlusADAPTIVE-CONTROL-
dc.subject.keywordPlusSTABILIZATION-
dc.subject.keywordPlusCOMPENSATION-
dc.subject.keywordPlusCOMPRESSORS-
dc.subject.keywordPlusSTABILITY-
dc.relation.journalResearchAreaAutomation & Control Systems-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalWebOfScienceCategoryAutomation & Control Systems-
dc.relation.journalWebOfScienceCategoryEngineering, Chemical-
dc.description.journalRegisteredClasssci-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > School of Chemical Engineering and Material Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Chul-Jin photo

Lee, Chul-Jin
대학원 (지능형에너지산업융합학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE