Detailed Information

Cited 6 time in webofscience Cited 8 time in scopus
Metadata Downloads

Predicting clinical outcomes using phase angle as assessed by bioelectrical impedance analysis in maintenance hemodialysis patients

Authors
Shin, Jung-hoKim, Chae RimPark, Ki HyunHwang, Jin HoKim, Su Hyun
Issue Date
Sep-2017
Publisher
ELSEVIER SCIENCE INC
Keywords
Phase angle; Bioelectrical impedance analysis; Outcomes; Hemodialysis
Citation
NUTRITION, v.41, pp 7 - 13
Pages
7
Journal Title
NUTRITION
Volume
41
Start Page
7
End Page
13
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/3964
DOI
10.1016/j.nut.2017.02.013
ISSN
0899-9007
1873-1244
Abstract
Objective: Protein-energy wasting is common in patients on hemodialysis and is an independent risk factor for adverse events. The aim of this study was to retrospectively investigate whether phase angle (PA), known as a nutritional marker, can predict various clinical outcomes in patients with end-stage renal disease (ESRD) who are receiving hemodialysis. Methods: Using bioelectrical impedance analysis (BIA), PA was obtained every 6 mo, and patients were divided into two groups according to baseline PA: group A included patients with PA >= 4.5 degrees, and group B included patients with PA <4.5 degrees. Results: We followed 142 patients for a median of 29 mo (12-42 mo). We found that a decrease in PA was associated with an increased risk for death that persisted after adjusting for age, sex, and comorbidities (hazard ratio [HR], 0.56; 95% confidence interval [CI], 0.33-0.97). Cardiovascular events were not associated with PA (P = 0.685). We found that PA predicted the occurrence of infection, independent of age, sex, and comorbidities (HR, 0.65; 95% CI, 0.45-0.94). Although levels of hemoglobin did not differ between groups during the study period, patients in group B received higher doses of erythropoiesis-stimulating agents and intravenous iron than those in group A (P = 0.004 and 0.044, respectively). In longitudinal analyses, we did not find increases in PA over time in patients who had a mean dialysis adequacy >= 1.4, daily protein catabolic rate >= 1.2 g/kg, or total carbon dioxide level >= 22 mmol/L. Conclusions: PA assessed in a simple manner using BIA provides practical information to predict clinical outcomes in ESRD patients on maintenance hemodialysis. (C) 2017 Elsevier Inc. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > College of Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Su Hyun photo

Kim, Su Hyun
의과대학 (의학부(임상-광명))
Read more

Altmetrics

Total Views & Downloads

BROWSE