Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

A comprehensive analysis of bio-inspired design of femoral stem on primary and secondary stabilities using mechanoregulatory algorithm

Authors
Mehboob, HassanAhmad, FurqanTarlochan, FarisMehboob, AliChang, Seung Hwan
Issue Date
Dec-2020
Publisher
SPRINGER HEIDELBERG
Keywords
Porous stem; Finite element analysis; Mechanoregulatory algorithm; Stress shielding; Stem stability
Citation
BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, v.19, no.6, pp 2213 - 2226
Pages
14
Journal Title
BIOMECHANICS AND MODELING IN MECHANOBIOLOGY
Volume
19
Number
6
Start Page
2213
End Page
2226
URI
https://scholarworks.bwise.kr/cau/handle/2019.sw.cau/41612
DOI
10.1007/s10237-020-01334-3
ISSN
1617-7959
1617-7940
Abstract
The coated porous section of stem surface is initially filled with callus that undergoes osseointegration process, which develops a bond between stem and bone, lessens the micromotions and transfers stresses to the bone, proximally. This phenomenon attributes to primary and secondary stabilities of the stems that exhibit trade-off the stem stiffness. This study attempts to ascertain the influence of stem stiffness on peri-prosthetic bone formation and stress shielding when in silico models of solid CoCr alloy and Ti alloy stems, and porous Ti stems (53.8 GPa and 31.5 GPa Young's moduli) were implanted. A tissue differentiation predictive mechanoregulation algorithm was employed to estimate the evolutionary bond between bone and stem interfaces with 0.5-mm- and 1-mm-thick calluses. The results revealed that the high stiffness stems yielded higher stress shielding and lower micromotions than that of low stiffness stems. Contrarily, bone formation around solid Ti alloy stem and porous Ti 53.8 GPa stem was augmented in 0.5-mm- and 1-mm-thick calluses, respectively. All designs of stems exhibited different rates of bone formation, diverse initial micromotions and stress shielding; however, long-term bone formation was coherent with different stress shielding. Therefore, contemplating the secondary stability of the stems, low stiffness stem (Ti 53.8 GPa) gave superior biomechanical performance than that of high stiffness stems.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > School of Mechanical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Chang, Seung-Hwan photo

Chang, Seung-Hwan
공과대학 (기계공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE