Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Flexible MoS2-Polyimide Electrode for Electrochemical Biosensors and Their Applications for the Highly Sensitive Quantification of Endocrine Hormones: PTH, T3, and T4

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Hyeong-U-
dc.contributor.authorKim, Hye Youn-
dc.contributor.authorSeok, Hyunho-
dc.contributor.authorKanade, Vinit-
dc.contributor.authorYoo, Hocheon-
dc.contributor.authorPark, Kyu-Young-
dc.contributor.authorLee, Jae-Hyun-
dc.contributor.authorLee, Min-Ho-
dc.contributor.authorKim, Taesung-
dc.date.available2020-07-15T05:23:16Z-
dc.date.issued2020-05-05-
dc.identifier.issn0003-2700-
dc.identifier.issn1520-6882-
dc.identifier.urihttps://scholarworks.bwise.kr/cau/handle/2019.sw.cau/41920-
dc.description.abstractFlexibile biosensors have a lot of applications in measuring the concentration of target bioanalytes. In combination with its flexibility, electrochemical sensors containing 2D materials have particular advantages such as enlarged area compatibility, transparency, and high scalability. A flexible biosensor was fabricated by direct synthesis of molybdenum disulfide (MoS2) on a polyimide (PI) substrate, which can be used as the working electrode in electrochemistry platforms. The direct formation of 2D-MoS2 on the PI was achieved using plasma-enhanced chemical vapor deposition (PE-CVD). Since the MoS2 provides higher electrical conductivity, the MoS2-Au-PI flexible sensor is able to provide highly sensitive detection of target proteins with a relatively fast response via cyclic voltammetry. To evaluate the high performance of the fabricated sensor, we selected the endocrine-related hormones parathyroid hormone (PTH), triiodothyronine (T3), and thyroxine (T4) as analytes because they are one of the most important markers for the determination of endocrinopathy, however, they are very difficult to quantify. The newly developed biosensor achieved highly sensitive detection of the hormones and could determine their location with high accuracy. In addition, we performed electrochemical measurements of hormones obtained from 30 clinical patients' sera with confirmed agreement and compared with the measurements performed with standard immunoassay equipment (E 170, Roche Diagnostics, Germany).-
dc.format.extent7-
dc.language영어-
dc.language.isoENG-
dc.publisherAMER CHEMICAL SOC-
dc.titleFlexible MoS2-Polyimide Electrode for Electrochemical Biosensors and Their Applications for the Highly Sensitive Quantification of Endocrine Hormones: PTH, T3, and T4-
dc.typeArticle-
dc.identifier.doi10.1021/acs.analchem.9b05172-
dc.identifier.bibliographicCitationANALYTICAL CHEMISTRY, v.92, no.9, pp 6327 - 6333-
dc.description.isOpenAccessN-
dc.identifier.wosid000530658600023-
dc.identifier.scopusid2-s2.0-85084939248-
dc.citation.endPage6333-
dc.citation.number9-
dc.citation.startPage6327-
dc.citation.titleANALYTICAL CHEMISTRY-
dc.citation.volume92-
dc.type.docTypeArticle-
dc.publisher.location미국-
dc.subject.keywordPlusPARATHYROID-HORMONE-
dc.subject.keywordPlusMOS2-
dc.subject.keywordPlusLAYERS-
dc.subject.keywordPlusFILM-
dc.subject.keywordPlusARRAYS-
dc.subject.keywordPlusSENSOR-
dc.subject.keywordPlusELISA-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of ICT Engineering > School of Integrative Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Min-Ho photo

Lee, Min-Ho
창의ICT공과대학 (융합공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE